3.11. Data holding, B/L

Press the “Hold B/L” switch, the presently measured value is held on LCD, press it again, the function is
cancelled. Press “Hold B/L” key to turn on the backlight

3.12. Automatic power off

• The meter will be into sleeping mode when it works for (15±10) minutes. Press “POWER” key twice to

restart the power.

3.13. Hot Wire Test

• Insert the red test lead into the ΩHzV terminal and the black test lead into theCOM terminal.
• Set the knob to TEST range, and set the red test lead to the tested circuit.
• If LCD displays “OL” and the light and sound alarming, it means the circuit of the red test lead tested

is hot wire, if there is no any response, it means it is neutral wire.

Notes
• The function is only for testing AC (AC 110V~AC380V)

4. Maintenance of the Instrument

This instrument is precise, and users shall never change its circuit at random.
• Protect the instrument from water, dust and hurl-down.
• Never store or use the instrument in high-temperature, high-humidity, flammable, explosive and

strong-magnetic-field environment;

• Please clean the outer surface of the instrument with wet fabric and gentle detergent, instead of grinding

additives and strong solvents like alcohol, etc.;

• If the instrument is left unused for long term, the battery shall be taken out in order to avoid that the

instrument is eroded by battery weeping;

• When

symbol displays, should replace the battery.

• For replacement of fuse, please use fuse of the same specification and model.
Notes
• Don’t connect the voltage higher than DC1000V or AC750V peak value;
• Don’t use this instrument is the batteries are not installed or the back cover is not fastened;
• Please move the testing probes from tested points and shut down the machine before replacement of

batteries or fuse.

Summary of Contents for AX-582B

Page 1: ...o avoid fault operation Please do not measuring before battery isn t installed and back cap isn t firm Do not input any voltage when measure resistance Always remove the test leads before replacing th...

Page 2: ...3 100mV 1000V 1 0 10 1V Input impedance 10M Over load protection 250V DC or AC peak value for range 200mV 1000V DC or AC peak value for other ranges 2 2 3 AC Voltage Measurement Range Accuracy Resolu...

Page 3: ...se Frequency response 40 200 Hz Display Sine wave RMS Average value response 2 2 6 Resistance Range Accuracy Resolution 200 0 8 5 0 1 2k 0 8 3 1 20k 0 8 3 10 200k 0 8 3 100 2M 0 8 3 1k 200M 5 0 20 100...

Page 4: ...is approx 1mA the backward voltage is approx 3V Value displayed Buzzer sounds the resistance is less than 50 20 Testing condition Open voltage is approx 3V Overload protection DC or AC250V peak value...

Page 5: ...3 Application Method 3 1 Description of operating panel 1 LCD unit It displays the numerical value measured with the instrument and its unit 2 1 Power ON OFF 2 2 HOLD B L 2 3 MIN MAX key...

Page 6: ...ut to DC Voltage above 1000V or AC above 750V RMS Never contact the high voltage circuit measured 3 3 AC Voltage Measurement Insert the black multimeter probe into COM end and the red multimeter probe...

Page 7: ...ange and the range switch shall be rotated to a higher level The maximum input current is 200mA or 20A depending on the inserting location of red probe In case of exceeding rated current the fuse will...

Page 8: ...5kHz Notes The initial square wave output is 50Hz if want to output different frequency press HOLD to choose CAUTION do not input voltage at this range 3 9 Diode and on off test Insert the black multi...

Page 9: ...is instrument is precise and users shall never change its circuit at random Protect the instrument from water dust and hurl down Never store or use the instrument in high temperature high humidity fla...

Page 10: ...not connected Holding switch Replace the batteries Appearance of the sign Replace the batteries No input of current Replace the fuse Big error in display Replace the batteries The specifications are s...

Reviews: