If the edge of joists are detected, the center arrow symbol will illumine and the beeps will ring, at this time,
make a mark on the edge of detected object through the marker slot by pencil. Then continue to move the unit
slowly in the same way until the arrow symbol goes out and the beeps stop.
Repeat the steps above from the opposite direction to detect the other edge of the target object and make a mark;
the center of the two markers is just the center of the detected object. Repeat the operations for several times to
get the relatively precise result.
Notice
If the power button released incautiously, you must restart the calibration and repeat the steps above to detect.

6.2. AC live wire detection detecting the AC live wire through walls

According to the calibration requirements for AC live wire detection, calibrate the tool to the ideal induction.
Operate the tool and find out the two edges of AC live wires and make a mark with reference to the method of
“Joist detection: detecting joists through walls”. The center of the two marks is just the center of AC live wire.
Notice
AC live wires in metal pipes or metal covered wire, as well as metal walls or walls of high density all cannot
be detected.

6.3. Metal object detection detecting the metal stud through walls

According to the calibration requirements for metal stud detection, calibrate the tool to the ideal induction.
Operate the tool and find out the two edges of metal studs and make a mark with reference to the method of
“Joist detection: detecting joists through walls”. The center of the two marks is just the center of metal stud.

6.4. Tips

• The tool can accurately detect the center of the target object, but the width of the target object can only be

detected in a range.

• Please do not use the tool near strong electric wave or high frequency interference.
• Please do not use the scanner in high temperature and wet place.
• Please try to avoid using the tool on wet plate and wall.
• Sometimes, the scanner cannot detect the slate or mixed plate correctly because the density of the materials

change a lot.

• When tacking, cutting or drilling on the wall, ceiling or floor, please take care to the wires and pipes on the

back of them.

• The covered wires, useless wires, telephone lines, CATV wires and circuitries without electricity could not

be detected as live wires.

• When the thickness of detected wall is over 2cm or the joists are close to each other, joist detection is not

suitable, generally, the space between joists is 40 or 60cm, and the width of the joist is 3,8 cm.

• The detection is not suitable for metal wall or the wall with high density materials of metal.
• When constructing beside the AC live wires, the power supply should be switched off.

Summary of Contents for AX-904

Page 1: ...h care because the pin is sharp Do not push the metal pins into material other than dry wall or wood as breakage of the pins and the tool may occur Remove the batteries when storing the tool for an extended time to avoid damage to the tool caused by batteries deteriorate Laser mark function The tool can generate a visible red laser line on the surface of objects It is convenient for you to choose ...

Page 2: ...easuring result D Mode switch Set the mode for wood joists AC live wires or metals E Addition key Add the measured length area or volume F Detection button Press the button to detect when detecting G READ On read key Press this key to start the tool and read the measured distance keep pressing this key and move the tool to read dynamic result H RM Memory read key Read out and display the result of...

Page 3: ...oaching the target object the two symbols will light in turn towards the center symbol when approaching the edge of the detected object G Symbol for central arrow the light is on when detecting the edge of the detected object H Measurement units I Caution symbol for AC live wires the symbol is light when AC live wire is detected J Current measuring result K Joist detecting indication the light is ...

Page 4: ...t Tips In the DISTANCE mode the backlight will be automatically light and go out without pressing the key within 15s Press any key to turn on the backlight again In the DISTANCE mode the tool will turn off automatically without pressing key within 30s Press READ key to turn on it The value before turning off will display on the screen The tool will have sound indication when pressing the key It sh...

Page 5: ...tween the length area volume and length mea surement If there are datum on the display first pressing the MODE key will clear the current datum and the mode will be invariable 4 6 Addition of area under area mode Press the M key to save the calculated area of first time measurement at the same time the M icon appears on the screen Press MODE key to clear the current displayed data then can begin t...

Page 6: ...ill appear on LCD Press MODE key to clear the current displayed data then can begin the second time measurement and computation Follow step 1 to 3 under the volume section After getting the calculated volume of second time press key to enter the addition mode A icon would appear on LCD Press RM key to recall the first calculated volume for the addition The M icon will disappear and the stored memo...

Page 7: ...re the tool will automatically set to the most ideal induction according to the distance 5 4 Detecting calibration for metal objects Set the mode switch to the mode for metal object and then calibrate the tool with reference to the method of detecting calibration for joist Notice when calibrating the tool will automatically set the degree of induction according to the existence of the metal object...

Page 8: ...tal stud through walls According to the calibration requirements for metal stud detection calibrate the tool to the ideal induction Operate the tool and find out the two edges of metal studs and make a mark with reference to the method of Joist detection detecting joists through walls The center of the two marks is just the center of metal stud 6 4 Tips The tool can accurately detect the center of...

Page 9: ... the push pin protect buckle has been retracted to original place to avoid damage 7 3 Laser mark Take measurement and determine where the laser line needs to be projected Measure for position of laser line See How to fix the tool Determine laser orientation Do not stare into the laser beam See Safety Instructions a Horizontal line turn the tool left or right until the bubble above the tool is betw...

Page 10: ...here is no action of pressing keyboard in 15s Object of detection Joists AC live wires and Metals Detection capability Joist Thickness of wall is 19mm Detection capability AC live wire 50mm 2 inches deep away from the wall Detection capability Metals 38mm 1 1 2 inches deep away from the wall Power supply One 9V battery Power consumption 50mA Operating temperature 5 C 40 C Operating humidity 30 70 ...

Reviews: