AX-3003P AX-6003P

1. Use of Operation Manual

Please read through and understand this Operation Manual
before operating the product. After reading, always keep the
manual nearby so that you may refer to it as needed. When
moving the product to another location, be sure to bring the
manual as well.

2. Safety instructions

2.1. Safety Terms and Symbols

This chapter contains important safety instructions that you
must follow when operating the instrument and when keep-
ing it in storage. Read the following before any operation
to insure your safety and to keep the best condition for the
instrument.
The following safety symbols may appear in this manual or
on the instrument:

WARNING - Identifies conditions or practices that could
result in injury or loss of life.

CAUTION - Identifies conditions or practices that could
result in damage to the instrument or to other properties.

DANGER - High voltage

ATTENTION - Refer to the manual

Earth (ground) terminal

Protective conductor terminal

2.2. Safety Guidelines

Before plugging into local AC mains, check and make
sure that the output voltage is compatible to the load. (It
is suggested to disconnect a load before plugging into
local AC mains.

Do not use this instrument near water.

Do not operate or touch this instrument with wet hands.

Do not open the casing of the instrument when it is

connected to AC mains.

The max.output voltage of the instrument may be over
60VDC, avoid touch the metal contact part of the output
terminals.

Summary of Contents for AX-3003P

Page 1: ...ear in this manual or on the instrument WARNING Identifies conditions or practices that could result in injury or loss of life CAUTION Identifies conditions or practices that could result in damage to...

Page 2: ...round to avoid electrical shock 2 4 Fuse Make sure the correct type of fuse is installed before power up Replace the AC fuse with the same type and rating as the original fuse Disconnect the power cor...

Page 3: ...instruments directly from panel control knob Besides when the remote controller is on line the Lock key light turns on and the operation can only be proceed through it At this time all the panel opera...

Page 4: ...omplete step voltage value setup Press key V Set I Set again until Voltage is shown on the LCD Press keys Shift to increase the voltage by 1 1V or press keys Shift to decrease the voltage by 1 1V Re p...

Page 5: ...current will automatically stop the OCP indicator turns on and warning signal by the beeper will be heard Press key OVP OCP until OCP Set is shown on the LCD Setting method 1 Press Number key current...

Page 6: ...ltage at the output terminal 8 14 Recall the Setting Data from the Memory Bank Press key Menu or Recall Store until Utility Recall is shown on the LCD use the number key to input the memory address to...

Page 7: ...key is for turning on or off the output 8 22 Lock The Lock key is for locking up the panel setting When the key light turns on the other key and knob is disabled except Lock and Output key 8 23 CV CC...

Page 8: ...on Check whether the CC indicator is on or not to make sure the output operation is under the constant current mode If the CV indicator is on it needs to enlarge its voltage limit value to assure that...

Page 9: ...z 1MHz 2mV rms I 3A 5Hz 1MHz Temp co efficient 300ppm C Setting accuracy 0 03 of reading 10mV 25 5 C Current output Line regulation 0 2 3mA Load regulation 0 2 3mA I 3A 0 2 5mA I 3A Ripple Noise 3mA r...

Page 10: ...Dimension 296 D 126 W 143 H mm Weight 5 5kg Maximum Setting Value Model AX 3003P AX 6003P Output range Item 30V 3A 60V 3A Output voltage 32V 62V Output current 3 2A 3 2A...