Lens Replacement - Instructions
EN
GL
ISH
Instructions
Follow these instructions to replace the lens. In order to set the focus and position the lens, the camera must be
connected to the network. For instructions, please refer to the Installation Guide supplied with the camera.
Important!
Detaching/attaching the lens with force may cause irreparable damage to the lens holder, no force is needed.
Follow the instructions below to replace the lens
on the following models :
• AXIS M3011
• AXIS 209FD
• AXIS 209FD-R
• AXIS 209FD-R M12
• AXIS 209MFD
• AXIS 209MFD-R M12/SPLIT
• AXIS 209MFD-R
• AXIS 209MFD-R M12
• AXIS 209MFD-R M12/SPLIT
Note:
Applies to P/N 0283-00X-
08 or higher
P/N is located on the product label
Replace the lens
Follow these instructions to replace the lens:
1. Remove the dome cover, see FIG.1a and FIG.1b.
2. Unlock the lens lock screw by turning it 180°, counter-clockwise (Fig. 2).
3. Rotate the lens counter-clockwise to detach it (Fig. 2).
4. Carefully attach the new lens and be sure to insert it gently, no force is
needed.
Set the focus
In order to set the focus and position the lens, the camera must be connected to the network. For instructions, please
refer to the Installation Guide supplied with the camera. After installation, follow the instructions below:
Note:
Due to the dome’s refraction, the image might appear slightly out of focus once the dome has been placed. To
compensate, focus on an object slightly closer than the intended area.
E.g. for AXIS 209MFD 16MM lens, rotate approximately 270 degrees counter-clockwise before attaching the dome.
1. Open the camera’s Live View page in a web browser.
2. To adjust the focus, manually rotate the lens until the image on the Live View page is satisfactory.
3. Gently lock the lens by turning the lens lock screw approximately 180° clockwise, until it clicks in place.
Camera unit - AXIS 209FD
Dome cover
Fig.1a
Camera unit - AXIS M3011
Fig.1b
Dome cover
installed in ceiling
Ceiling
Lens lock screw
Lens
Fig.2
Lens
holder