AXIS A9188 Network I/O Relay Module
•
When the Axis product has reached the end of its useful life, dispose of it according
to local laws and regulations. The product should not be disposed of together with
household or commercial waste. See
Disposal and recycling on page 3
•
Battery
-
The 3.0 V lithium battery used by the Axis product is a UL Recognized
component. (Type: BR2032, diameter: 20 mm (0.78 in), manufacturers:
Rayovac, Panasonic). The following battery type is also a UL Recognized
component: Type CR2032, manufacturers: Fuji, Maxell, Renata, Varta,
Panasonic, JHIH
-
Users shall not replace the battery. If the battery needs replacing,
a factory trained service professional shall contact Axis support
at
www.axis.com/techsup
for assistance.
-
Used batteries shall be disposed of according to local laws and regulations,
which may vary from state to state. Waste BR/CR lithium cells are neither
listed nor exempted from the USEPA hazardous waste regulations. Waste
lithium batteries can be considered reactive hazardous waste if there is a
significant amount of unreacted, or unconsumed lithium remaining. For
information about how to dispose of used lithium batteries, contact your local
authority for waste disposal.
Specifications
•
Operating Conditions
-
Classification IEC 60721-4-3 Class 3M3
-
Temperatures -35°C to 66°C (31 °F to 150.8 °F).
-
Humidity 20–85% RH (non-condensing)
•
Wire area
-
UL Listed or R/C AWM wires that have an conductor gauge range of
AWG 22–14 shall be used.
-
The minimum conductor gauge for connection between the power sourcing
equipment (PSE) or power injector and the powered device (PD) is 26 AWG.
•
Connectors
-
This product is not intended for outside wiring as covered by Article 800 in the
National Electrical Code, NFPA 70.
-
Power Connector – For UL security applications, the product shall be powered
by a UL 294 Listed or UL 603 Listed Class 2 low-voltage power SELV and
limited power supply that is capable of 4 hours of standby power.
-
External power to relays - If the relays are connected to an external power
source this must be UL 294 Listed or UL 603 Listed Class 2 low-voltage power
SELV and limited power supply that is capable of 4 hours of standby power.
-
Network Connector – Power over Ethernet (PoE) shall be supplied by a UL 294
Listed Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3 or Power over
Ethernet Plus (PoE+) IEEE 802.3at Type 2 Class 4 power limited injector that
provides 44–57 V DC, 15.4 W / 30 W and 4 hours of standby power.