USER MANUAL
35
_________________________________________________________________________________________________________________
17.4
Serial port parameters setting (SErIAL)
The function allows setting independently
communication parameters of both of serial ports
Port-1
and
Port-2
(executed in RS232C, RS485,
USB or LAN standard):
-
transfer protocol
(Prot):
LonG
–
cooperation with printer or computer
,
EPL
–
cooperation with label printer in normal mode
(activates
LAbEL
function),
EPL_A
–
cooperation with label printer in automatic
mode (activates
LAbEL
function),
EPL_d
–
cooperation with special label printers,
Pen-01
–
cooperation with PEN-01,
-
baud rate
(bAud):
(
4800, 9600, ….115 200bps
),
-
number of bits in single char.
(bitS): 7, 8
,
-
parity control
(PArItY):
nonE
–
no control
Odd
–
nonparity
Even
–
parity control,
-
scale number in network
(nr):
(if the scale does
n’t work in network the number
must be 0)
,
-
transmission through serial interface
(SendInG)
:
StAb
–
transmission after
key is used and
result is stable,
noStAb
–
transmission after
key is pressed
without need of stabilisation,
Auto -
automatic transmission after load is put on
and result is stable
(Auto)
,
Cont -
continuous transmission, about 10 results
per second (
Cont.),
Remove
- trans
Default parameter values:
Long, 9600 bps, 8 bits, none,
StAb,
-
SCAnn
–
cooperation with MJ-4209 barcode
readers.
In order to set needed parameters choose
SErIAL
function, select appropriate parameter and press
T
key when required option or parameter value is displayed.
In scales with an additional serial port appear
Port-1
and
Port-2
, for the independent setting of both ports.