AXIS Q1604 Network Camera
Connectors
I/O Connector
4–pin terminal block
4
3
2
1
For an example diagram, see
Connection Diagrams on page 16
Function
Pin
Notes
Specifications
0 V DC (-)
1
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3.3 V DC
Max load = 50 mA
Digital Input
3
Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
0 to max 40 V DC
Digital
Output
4
Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used
with an inductive load, e.g. a relay, a diode
must be connected in parallel with the load,
for protection against voltage transients.
0 to max 40 V DC, open
drain, 100 mA
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage
(SELV) compliant limited power source (LPS) with either a rated output
power limited to
≤
100 W or a rated output current limited to
≤
5 A.
Audio Connector
3.5 mm audio
connectors (stereo)