AXIS T99A11 Positioning Unit 24 V AC/DC
Temperature
Humidity
Normal: -50 °C to 60 °C (-58 °F to 140 °F)
Maximum (intermittent): 65 °C (149 °F)
Cold start: -40 °C to 60 °C (-40 °F to 140 °F)
10–100% RH
(non-condensing)
The start–up time is 2 minutes at 0 °C to 50 °C (32 °F to 122 °F).
Power consumption
Typical consumption
Max consumption
10 W
169 W
Important
When using the 22 m (72 ft) AXIS Cable 24 V DC/24–240 V AC, a power supply capable of
delivering 220 W is required to compensate for the power loss in the cable.
NO
NO
NOTICE
TICE
TICE
The typical power consumption values are based on the following:
• Any losses in the power cable disregarded
• No positioning active
• Temperature at 25 °C / 77 °F (all heaters off)
• One H.264 stream at maximum resolution
• MJPEG stream recorded to SD card
38