Installation Manual
Page 14 / 16
4.10.
Overcurrent protection type: None // Number of By-pass diodes: 3
4.11.
Diameter of cables. Every module has (2) cables whose diameter is 4mm
2
for each of
them, and it can endure 90
℃
insulation and can be exposed under sun light.
Ways of connecting: Every module comes with (2) connectors and they are
respectively positive electrode and negative electrode. When modules are installed in
series, the first positive connector should connect with the negative connector of the
next module. The modules are equipped with PV wiring connectors that comply with
the Standard for Connectors for Use in Photovoltaic Systems, UL 6703, the specific
allowable mating connector manufacturer(s) and model number(s) are listed as
below, different model connectors should not be mated with each other.
Connector model name
Allowable mating connector model name
PV-ZH202-SBN
PV-ZH202-SBN
TL-Cable01
TL-Cable01
PV-JM601
PV-JM601
PV-ZH202B Series
PV-ZH202B Series
TL-CABLE01S-FM
TL-CABLE01S-FF
PV-JM601A
PV-JM601A
PV-JM608
PV-JM608
PV-KST4-EVO2/6II-UR
PV-KBT4-EV02/6II-UR
PV-KST4/6II-UR
PV-KBT4/6II-UR
UTXCFA4AI, UTXCFA4AC or UTXCFA4AM
UTXCMA4AI, UTXCMA4AC or UTXCMA4AM
5.
Operation and Maintenance
5.1.
No routine maintenance is required. However, it is advisable to perform periodic
inspection of the modules for damage to glass, back-skin, or frame. Check electrical
connections for loose connections and corrosion.