Installation Manual
Page 15 / 16
5.2.
Photovoltaic modules can operate effectively without ever being washed, although
removal of dirt from the front glass can increase output. The glass can be washed with
a wet sponge or cloth. Wear rubber gloves for electrical insulation.
6.
Transport, Storage Modules
6.1.
Modules should
NOT
be in a vertical position while in transport.
6.2.
When moving the modules, use both hands to grasp the module frame,
DO NOT
pull
the cable leads on the junction box.
6.3.
It is strictly prohibited to transform, adapt, modify or rebuild a module.
6.4.
DO NOT
place any heavy articles/objects on the modules (i.e. tools).
6.5.
DO NOT
stand and/or walk on the modules. There should not be any external force
applied to the module
6.6.
DO NOT
scratch the back sheet (rear surface) of the modules.
6.7.
To keep all of the electrical contacts in good working condition keep modules in a dry
and un-contaminated area, prior to installing.
6.8.
If temporary storage is needed, the storage space should be a dry, well ventilated
area.
7.
Module information
7.1.
Type: AC-"XXX"P/72V; AC-"XXX"M/72V; AC-"XXX"P/72XV; AC-"XXX"M/72XV; AC-
"XXX"P/60V; AC-"XXX"M/60V; AC-"XXX"P/60XV; AC-"XXX"M/60XV
(XXX is power rating)
Standard test condition: 1000W/m
2
, AM1.5, at 25°C
Module application: Class A
Module Fire Performance: Type 1 or Class C (for CUL)
Recommended maximum Series/Parallel module configuration: 24/1 for models as
follows: AC-"XXX"P/72V; AC-"XXX"M/72V; AC-"XXX"P/72XV; AC-"XXX"M/72XV
29/1 for models as follows: AC-"XXX"P/60V; AC-"XXX"M/60V; AC-"XXX"P/60XV; AC-
"XXX"M/60XV
Maximum series fuse: 20A / Maximum system voltage: 1500V
7.2.
Type: AC-"XXX"P/72S; AC-"XXX"M/72S; AC-"XXX"P/72X; AC-"XXX"M/72X; AC-
"XXX"P/60S; AC-"XXX"M/60S; AC-"XXX"P/60X; AC-"XXX"M/60X
(XXX is power rating)
Standard test condition: 1000W/m
2
, AM1.5, at 25°C