Installation Manual
Page 7 / 16
Table 3.6-1 Install methods(Valid for 3.6.1 and 3.6.2)
Low/normal level loading condition(Apply to
most of environment conditions, rated load
is 1600Pa, safety factor is 1.5)
High level loading condition(Apply to harsher
environment conditions, such as storm, heavy snow
etc. Rated load is 3600Pa, safety factor is 1.5)
Mounting
system
Clamping
system(At
tach to
the long
frame)
Permissible range of clamp
0<S≤
1/4L
Permissible range of clamp
(1/4L-50)
<S≤
(1/4L+50)
Clamping
system(At
tach to
the short
frame)
Permissible range of clamp
0<H
≤
1/4W