Installationsanleitung AXIbox 11K
EN211103
11
7 Troubleshooting
7.1 Error detection via LED-indicator
State
Description
LED State
Standby
Normal
Flashing green, 1S on, 4S off
Charging
Normal
Breathing green, 1S on, 1S off
Cable connected
Normal
Breathing yellow, 1S on, 1S off
Software upgrade
Normal
Green light flash
Ground warning
Normal
Flashing yellow, 2S on, 2S off
Relay adhesion
Fault
Red light normally on
Input polarity reverse
Fault
Flashing red, 500ms on, 500ms off, 1 time, 3S off, Cycle
CP fault
Fault
Flashing red, 500ms on, 500ms off, 2 times, 3S off, Cycle
Leakage current fault
Fault
Flashing red, 500ms on, 500ms off, 3 times, 3S off, Cycle
Input terminal
overtemperature
Fault
Flashing red, 500ms on, 500ms off, 4 times, 3S off, Cycle
Relay overtemperature
Fault
Flashing red, 500ms on, 500ms off, 5 times, 3S off, Cycle
Under voltage fault
Fault
Flashing red, 500ms on, 500ms off, 6 times, 3S off, Cycle
Over voltage fault
Fault
Flashing red, 500ms on, 500ms off, 7 times, 3S off, Cycle
Overload fault
Fault
Flashing red, 500ms on, 500ms off, 8 times, 3S off, Cycle
Over frequency fault
Fault
Flashing red, 500ms on, 500ms off, 9 times, 3S off, Cycle
Other frequency fault
Fault
Flashing red, 500ms on, 500ms off, 10 times, 3S off, Cycle
Leakage current loop
abnormal
Fault
Flashing red, 500ms on, 500ms off, 11 times, 3S off, Cycle