background image

What’s Included

03

Safety Precautions

Good Working Practices/Safety

The following suggestions will enable you to observe good working practices, keep yourself and fellow workers
safe and maintain your tools and equipment in good working order.

WARNING!!  KEEP TOOLS AND EQUIPMENT OUT OF THE REACH OF YOUNG 

CHILDREN

Air Powered Tools

1. Always perform pre-operation checks before
starting up the compressor.

2. Never leave inflammable objects or materials near
to the compressor.

3. Always check oil level before using the
compressor.

4. The cylinder, cylinder head and delivery pipe
become hot during use. Do not touch these items
while the compressor is running.  Allow to cool 
thoroughly after shut-down before handling.

5. Do not operate above the maximum working
pressure of 115 psi (7.8 bar).

6.  Avoid using the compressor with an extension
cable; this may reduce the supply voltage and make
the motor overheat. 

7. Switch the compressor on and off by using the
pressure switch knob (Fig 3); only switch off at the
mains in case of emergency.

8. Drain water from tank every day.

9. If the compressor shuts down through overload or
overheating check the reason for the shut-down

before re-starting.

10. Do not adjust the tank pressure switch without
reference to Axminster Power Tool Service
Department. 

11. Do not remove parts from the compressor whilst
it is running.

12. Do not operate the compressor with protective
covers removed or damaged.

13. When spray painting always work in a well
ventilated area and never close to open flames.

14. Never direct a jet of compressed air towards 
people or animals. Keep children and animals away
from the compressor.

15. Do not use on an inclined surface.

16. Only use in ambient temperatures between –40˚C
and +70˚C.

17. Only operate on 230 volt supply and with
maximum fuse rating of 13 amps.

Quantity

Item

Model Number

1 off: 

Air Compressor 

4 off Small Washers 

(D)

RAC106B

1 off 

Bottle of oil  

4 off M6 Spring Washers 

(E)

4 off 

Rubber Feet 

(A)

4 off M6 Nuts

(F)

4 off 

M6x25mm Bolts 

(B)

1 off  Filter 

(G)

4 off 

M6 Large Washers 

(C)

1 off Instruction Manual

Summary of Contents for AWC10HP

Page 1: ...h as air staplers and nailers air brush painting occasional tyre inflation etc Quite a robust little unit with a cast iron cylinder for long life Twin pressure gauges monitor receiver and output pressures Supplied with four rubber feet top grab handle for easy mobility output pressure control valve and a 1 4 BSP female quick release fitting Axminster Tool Centre Unit 10 Weycroft Avenue Axminster D...

Page 2: ...Manufactured by Qingdao D D Electromechanical Technologies Co Ltd 23rd FL D D Fortune Center No 182 6 Haier Road Qingdao Shandong 266000 P R China Model number RAC106B Air Compressor manufactured by Qingdao D D Electromechanical Technologies Co Ltd is in compliance with the standards determined in the following Council Directive EC Council Directive 2006 42 EC Low Voltage Directive 2006 95 EC Warn...

Page 3: ...on and off by using the pressure switch knob Fig 3 only switch off at the mains in case of emergency 8 Drain water from tank every day 9 If the compressor shuts down through overload or overheating check the reason for the shut down before re starting 10 Do not adjust the tank pressure switch without reference to Axminster Power Tool Service Department 11 Do not remove parts from the compressor wh...

Page 4: ...circle marked on the oil level indicator See page 05 The compressor is now ready for use Specification AWC10HP Air Compressor Assembly Instructions Code 501083 Rating Light Trade Power 750W Free Air Delivered 40psi 3 5cfm 90psi 2 4cfm Max Pressure 115psi Noise Level at 3 meters 70dB Receiver Volume 6 litres Oil Capacity 100ml Supply Requirements 230V Overall L x W x H 515 x 240 x 465mm Weight 14 5...

Page 5: ...ure relief valve Pressure regulator adjuster Tank pressure gauge A Outlet pressure gauge B Oil drain plug Fitting the quick release coupling Wrap some PTFE tape A around the outlet thread and screw on the 1 4 BSP female coupling B and lightly tighten with a spanner DO NOT OVERTIGHTEN A B A B Closed Open ...

Page 6: ... Description of Air Compressor Fig 1 Tank On Off switch Handle Wheel Rubber foot Motor cover Cylinder Pressure adjuster Outlet pressure gauge Tank pressure gauge Pressure switch Pressure relief valve Crankcase Water drain valve ...

Page 7: ...Illustration and Parts Description of Air Compressor 07 Quick release coupling Oil level indicator and drain plug Air inlet filter Filter Motor vents Pressure adjuster Oil filler plug Fig 2 ...

Page 8: ...tank and shuts off when the maximum tank pressure is reached The compressor is automatic in operation the pressure switch shuts the motor off when the maximum tank pressure is reached and re starts it when the pressure drops below a pre set level The cut in and cut out pressures are factory set and should not need to be altered NOTE It is advisable to fully drain the air from the tank if the compr...

Page 9: ...il still warm remove the oil filler plug place a suitable container under the drain plug and drain the oil right out Replace drain plug and refill to the level mark on the sight glass See figs 6 8 Yearly a Replace the air filter element b Check and clean the air intake and delivery valves c Check the non return valve and replace the seal between the crankcase and cover if necessary When components...

Page 10: ...Parts Breakdown 10 ...

Page 11: ...Parts List Wiring Diagram 11 ...

Page 12: ...or to cool down Disassemble the head and replace any broken components Carefully clean all sealing surfaces before re assembling Stop the compressor and contact Axminster Tool Centre Stop the compressor quickly Release any air in tank and replace the pressure switch Contact Axminster Tool Centre Bad electrical connections Motor winding burnt out Compressor head gasket blown or valve broken Crank b...

Reviews: