background image

20 

 

Multiple-scan setting 

Single-scan setting 

Option bar code 

Option 

Alpha. entry 

Keyboard type 

 

IBM AT, PS/2 

00* 

Apple Mac 
compatibles 

01 

 

Keyboard layout 

 

USA 

00* 

Turkish F 

01 

 

Turkish Q 

02 

 

French 

03 

 

Italian 

04 

 

Spanish 

05 

 

Slovak 

06 

 

Denmark 

07 

 

Japanese 

08 

 

German 

09 

 

Belgian 

10 

 

Russian 

11 

 

Czech 

12 

 

Character encoding system 

 

Refer to 

3-10 Handheld scan & some global settings

. 

Clock period   

 

60 us 

00 

 

70 us 

01 

 

80 us 

02* 

90 us 

03 

 

100 us 

04 

 

Summary of Contents for MICRELEC CS2600-BT

Page 1: ...CS2600 BT Cordless Image Scanner User Manual Version CS2600 BT_UM_EN_V2 2 5 ...

Page 2: ......

Page 3: ...erature changes can cause condensation to form on the scanner s case Operating the scanner while condensation is present can interfere with proper operation Take care to avoid conditions that cause the formation of condensation If condensation does form wait until it dries completely before using the scanner 10 If multi clusters are working in the same area it is strongly recommended that differen...

Page 4: ...attery by incinerating it or otherwise expose it to heat Doing so creates the danger of battery heat emission explosion and fire 6 Never allow the positive and negative terminals of the battery to become connected shorted by metal Doing so create the danger of battery heat emission explosion and fire 7 Never transport or store the battery together with a necklace hair pins or other metal objects D...

Page 5: ... the laser beam Doing so can cause serious eye damage Lithium ion battery 1 Do not put a battery in microwave ovens or pressure cookers Doing so may cause the battery to overheat explode or burst into flames 2 Do not use a battery that smells strange is overheating is a strange color or is a strange shape Doing so may cause the battery to overheat explode or burst into flames 3 If the amount of ti...

Page 6: ...r pull on the power cord Doing so creates the danger of fire and electrical shock 4 Use only the AC DC adaptor and charger specified in this manual Use of other AC DC adaptor models or chargers creates the danger of fire and electrical shock 5 Should the power cord ever become severely damaged contact your original dealer Use of a damaged electrical cord creates the danger of fire and electrical s...

Page 7: ... area subjected to large amounts of humidity or dust Doing so creates the danger of fire and electrical shock 3 Do not leave the unit for long periods in a car parked in direct sunlight Heavy objects Never place heavy objects on top of the unit Doing so creates the risk of a loss of balance and the object falling which can cause personal injury Scan window 1 Never apply strong pressure to the mirr...

Page 8: ...ren Do not let small children remove the battery from the charger or the unit it is powering Cradle with RS 232 cable and adaptor 1 Keep the power cord away from stoves and other sources of extreme heat Heat can melt the insulation of the power cord and create the danger of fire and electrical shock 2 Never pull on the power cord when unplugging it Doing so can damage the cord and create the dange...

Page 9: ...2 interface for cradle 23 3 9 USB interface for cradle 25 3 10 Handheld scan some global settings 28 3 11 Indication for handheld unit 33 3 12 Decode illumination and decode aiming pattern 34 3 13 Single type of barcode read 36 3 14 DPM Multiple symbols Structured append read etc 37 3 15 UPC A 39 3 16 UPC E 41 3 17 UPC E1 43 3 18 EAN 13 ISBN ISSN 45 3 19 EAN 8 47 3 20 Code 39 Code 32 Trioptic Code...

Page 10: ...Barcode representing non printable character 91 8 Return default parameters 92 8 1 CS2600 BT return default parameters 92 9 Display firmware version radio communication setting 93 9 1 CS2600 BT display firmware version 93 10 Configuration alphanumeric entry barcode 94 ...

Page 11: ...gle 70 75 360 Skew Pitch Roll Print Contrast 20 minimum reflectance difference Decoding Capability 1D UPC A UPC E UPC E1 EAN 13 EAN 8 ISBN Bookland EAN ISSN Code 39 Code 39 full ASCII Code 32 Trioptic Code 39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar NW7 Code 128 UCC EAN 128 ISBT 128 Code 93 Code 11 USD 8 MSI Plessey UK Plessey China Post GS1 DataBar formerly RSS variants 2D PDF41...

Page 12: ...nificantly affect the communication distance in practice The distance drops quickly in the rainy high humidity or heavy haze day radio interference also shortens the communication distance Cradle Input Voltage 5 0 25 VDC Current 60 mA working 500 mA charging Cable Straight 2 0 m PS 2 Straight 1 5 m USB Straight 2 0 m RS 232 Dimensions Length Width Depth 118 89 5 74 mm Weight 140 g without cable In...

Page 13: ...4 N Fm Code 128 1 K Cm UCC EAN 128 1 K Cm ISBT 128 1 K Cm Code 93 1 L Gm Code 11 4 V MSI Plessey 4 O Mm UK Plessey 1 U Mm China Post 11 2 T Im China Finance 10 2 Y GS1 DataBar 16 2 R em GS1 DataBar Truncated3 16 2 R em GS1 DataBar Limited 16 2 R em GS1 DataBar Expanded 1 R em PDF417 p Lm MicroPDF417 p Lm DataMatrix d dm QR code q Qm MicroQR Code q Qm Han Xin Code h Xm Aztec Code a zm Note 1 The se...

Page 14: ...V Power 5V 2 3 3V for interface auto selection purpose Ground for interface auto selection purpose 3 3V for interface auto selection purpose 3 Ground Ground Ground 4 3 3V for interface auto selection purpose Reserved Ground for interface auto selection purpose 5 TxD KeyClock Reserved 6 RxD KeyData Reserved 7 Reserved TermClock Reserved 8 Reserved TermData Reserved 9 CTS Reserved D 10 RTS Reserved ...

Page 15: ...5 2 2 Dimensions ...

Page 16: ...nds to turn on Beeper On base indicator Blue LED Successful decoding indicator Green LED Communication fail indicator Red LED Charging indicator Red Green LED Figure 2 3 Cradle Power indicator Blue LED Communication indicator Green LED Key Long press 10 seconds to restore factory default setting of cradle ...

Page 17: ...he handheld unit is turned on when the charging is in process When the charging process completes the red LED is turned off 2 Charging time 6 hours for fully charged 3 You can charge the battery via a USB port on the device or a 5 VDC power adapter Note The 5 VDC power adapter is an optional accessory Figure 2 4 ...

Page 18: ...r 2 Windows gives message on new hardware found USB HID input device found then driver will be installed on request 3 After successfully installing the new hardware message will be given hardware installed successfully and ready to use 4 If any problem encounters during the installation process please unplug the USB cable from the computer and repeat step 1 and 2 2 5 3 RS 232 cable 1 Connect the D...

Page 19: ...priate Single scan setting e g 0101D00 according to the user s demand Example To set Flow control to be XON XOFF Steps Scan the following barcode Multiple scan setting Step 1 Scan the Option barcode barcode e g 0101M according to the user s demand Step 2 To the right of the option barcode the necessary alphanumeric inputs are listed Scan two alphanumeric entries from 0 to 9 or A to F refer to 10 C...

Page 20: ...er string with various length of 2 4 or other values Example Set 0401 03 decimal 8002 0D0A hexadecimal 8202 01 decimal The customized QR code barcode contents and symbol are as following 0401D03 8002H0D0A 8202D01 2 Notes of making QR code barcode The model is chosen as M2 Other requirements e g ECC level Start mode etc are not specified Other notes 1 The contents of a QR code barcode can include s...

Page 21: ... host via Bluetooth and behaves like a keyboard SPP The scanner connects to the PC host via Bluetooth and behaves like there is a serial connection Cradle The scanner connects to the cradle Multiple scan setting Single scan setting Option barcode Option Alpha entry Bluetooth mode HID Keyboard 00 SPP 01 Cradle 02 ...

Page 22: ...ng the user can change the output speed of the scanner to match the speed of the host USB communication port Multiple scan setting Single scan setting Option barcode Option Alpha entry Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmark 07 Japanese 08 German 09 Belgian 10 Russian 11 Czech 12 Thai 13 Hungary 14 Inter character delay 00 99 1ms 00 99 10 ...

Page 23: ... will attempt to connect to the base at the same time the handheld terminal will make a beep beep beep sound If the connection is successful the handheld terminal can be used directly If the connection is unsuccessful the handheld terminal will make a beep beep sound and the red LED on the handheld will blinks 2 times and then turns off Disconnect The handheld terminal scan disconnects the bar cod...

Page 24: ...e as follows XXXX can be set as Bluetooth name the length is 1 30 characters support 0 9 a A z Z For example scan below setting barcode BTN 1234Md the Bluetooth will be named as 1234Md If the Bluetooth name is successful changed the beeper will have three beeps Bluetooth name display if you wish to display the Bluetooth name of handheld please scan the barcode below ...

Page 25: ...battery indicator If it is enabled while the power is low the power LED on the handheld unit flashes 4 times and the beeper emits 4 beeps Multiple scan setting Single scan setting Option barcode Option Alpha entry Auto turn off delay Disable 00 5 minutes 01 10minutes 02 20minutes 03 30minutes 04 1 hour 05 3 hours 06 8 hours 07 10 hours 08 12 hours 09 Wireless module turn off delay Disable 00 30 se...

Page 26: ...16 Multiple scan setting Single scan setting Option barcode Option Alpha entry Enable 01 ...

Page 27: ...cradle for example when a user holding the handheld unit walks back into range Standard batch The handheld unit starts storing barcode data after EBM Enter Batch Mode is scanned Data transmission is triggered by scanning SBD Send Batch Data If you want to output the total number of barcodes scanned when in Standard batch Mode scan BDN If you want to clear the stored data in the handheld terminal p...

Page 28: ...8 Multiple scan setting Single scan setting Option bar code Option Alpha entry Batch data mode Disable 00 Out of range batch 01 Standard batch 02 Enter batch mode Send batch data Total Records Clear data ...

Page 29: ... PC during power on Inter character delay This delay is inserted after each data character transmitted Inter byte delay This delay is inserted after each byte transmitted Normally a character is comprised of three or above bytes Block trans delay It is a delay timer between barcode data output This feature is used to transfer continually with shorter barcode data Caps Lock reversion By setting ena...

Page 30: ...pple Mac compatibles 01 Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmark 07 Japanese 08 German 09 Belgian 10 Russian 11 Czech 12 Character encoding system Refer to 3 10 Handheld scan some global settings Clock period 60 us 00 70 us 01 80 us 02 90 us 03 100 us 04 ...

Page 31: ...und key 0 ms 00 10 ms 01 20 ms 02 40 ms 03 80 ms 04 Numeric key Alphabetic key 00 Numeric keypad 01 Alt keypad 02 Power on simulation Disable 00 Enable 01 Inter character delay 0 ms 00 5 ms 01 10 ms 02 20 ms 03 40 ms 04 80 ms 05 Inter byte delay 1 ms 00 2 ms 01 4 ms 02 8 ms 03 Caps Lock reversion Disable 00 ...

Page 32: ...22 Multiple scan setting Single scan setting Option bar code Option Alpha entry Enable 01 Caps Lock override Disable 00 Enable 01 ...

Page 33: ...racter ACK NAK After transmitting data the scanner expects either an ACK acknowledge or NAK not acknowledge response from the host When a NAK is received the scanner transmits the same data again and waits for either an ACK or NAK After three unsuccessful attempts to send data when NAKs are received the scanner issues an error indication and discards the data Inter character delay Refer to Inter c...

Page 34: ...ting Single scan setting Option bar code Option Alpha entry 600 01 1200 02 2400 03 4800 04 9600 05 19200 06 38400 07 57600 08 115200 09 Parity None 00 Odd 01 Even 02 Data bit 8 bits 00 7 bits 01 Stop bit 1 bit 00 2 bits 01 ...

Page 35: ...COM_Text emulates some kind of serial key typing Note When changing USB Device Type the scanner automatically restarts Simple COM Port Emulation Please contact the manufacturer for the instruction Keyboard layout The scanner supports different national keyboard layouts Inter character delay This delay is inserted after each data character transmitted By selecting the user can change the output spe...

Page 36: ...Mac 01 USB virtual COM 02 Simple COM Port Emulation 03 Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmark 07 Japanese 08 German 09 Belgian 10 Russian 11 Czech 12 Thailand 13 Hungary 14 Character encoding system Refer to 3 10 Handheld scan some global settings Inter character delay 0 ms 00 ...

Page 37: ...27 Multiple scan setting Single scan setting Option bar code Option Alpha entry 5 ms 01 10 ms 02 20 ms 03 40 ms 04 60 ms 05 Numeric key Alphabetic key 00 Numeric keypad 01 Alt keypad 02 ...

Page 38: ...unction is only valid when the Scan mode is Auto detection Same barcode delay time If a barcode has been scanned and output once successfully the scan operation should be interrupted for delay time or the focus of the scanner must be moved away from the barcode beyond delay time to active scanning the same barcode When this feature is set to be 0xFF then the delay time is indefinite Double confirm...

Page 39: ... to be 00 the scanner will not store data And if the parameter is set to be FF the scanner will output data after stopping scanning Character encoding system A character encoding system consists of a code that pairs each character from a given repertoire Common examples include Morse code the Baudot code the ASCII and Unicode If the data received does not display with the proper characters e g dom...

Page 40: ... Continue 03 Good read on 04 Auto detection Good read on 06 Auto detection Good read off 07 Working mode of Auto detection In cradle 00 Always ON 01 Standby duration 4 seconds 00 8 seconds 01 16 seconds 02 24 seconds 03 30 seconds 04 1 minute 05 1 5 minutes 06 2 minutes 07 5 minutes 08 7 minutes 09 10 minutes 10 15 minutes 11 20 minutes 12 ...

Page 41: ... barcode delay time for 2D symbol 00 FF16 50 ms 00 FF16 00 08 Double confirm 00 09 00 none 00 09 00 Global max code length for 1D symbol 04 99 04 99 99 Global min code length for 1D symbol 01 99 01 99 04 Global G1 G6 string selection 00 66 00 none 00 66 00 Element amendment Disable 00 Enable 01 Character output restraint None 00 Printable character only 01 Alphanumeric character only 02 ...

Page 42: ...Option Alpha entry Decoder optimization Disable 00 Enable 01 Data output delay in continue scan mode 00 99 100 ms FF Never 00 FF16 00 Character encoding system ASCII 00 UTF 8 01 Windows 1251 02 Complete data output before next decode attempt Disable 00 Enable 01 ...

Page 43: ...le Beep tone duration This parameter can be adjusted for a good reading upon favorite usage Volume of beeper This parameter can be adjusted for different level of the volume of the beeper Vibrator indication After each successful reading the vibrator will vibrate to indicate a good barcode reading Multiple scan setting Single scan setting Option bar code Option Alpha entry Power on alert Disable 0...

Page 44: ... option is enabled the scanner will project the aiming pattern during the code capture Level of decode illumination This parameter can be adjusted for different level of decode illumination Illumination mode of Auto detection Always off Illumination LED will be always turned off Enable illumination in low light conditions In low light conditions the scanner will turn on illumination LED automatica...

Page 45: ... Flashing 02 On when reading 03 Decode aiming pattern Always Off 00 Always On 01 On before reading 02 On when reading 03 Level of decode illumination Disable decode illumination 00 Low 01 Middle 02 High 03 Illumination mode of Auto detection Always off 00 Enable illumination in low light conditions 01 Always on 02 ...

Page 46: ... Multiple scan setting Single scan setting Option barcode Option Alpha entry 1D symbols read Follow respective 1D symbol setting 00 All 1D Disable 01 All 1D Enable 02 2D symbols read Follow respective 2D symbol setting 00 All 2D Disable 01 All 2D Enable 02 Only PDF417 Enable 03 Only QR code Enable 04 Only Data Matrix Enable 05 Only Aztec Code Enable 07 ...

Page 47: ...ind and decode new symbols as long as the trigger is pulled 2 By setting Enable the scanner will output data only when all Structured Append symbols have been decoded The lower part of below figure shows an example of four Structured Append symbols with the same data as that in the upper symbol 3 By setting Disable the scanner will only read the symbol closest to the aiming beam Single symbol abov...

Page 48: ...Multiple scan setting Single scan setting Option bar code Option Alpha entry DPM format read Disable 00 Enable 01 structured append symbols read Disable 00 Enable 01 Mobile screen read Disable 00 Enable 01 ...

Page 49: ...r to Global insertion group selection of 3 10 Handheld scan some global settings Supplement digits The Supplement digits barcode is the supplemental 2 or 5 characters Format System character Data digits 10 digits Check digit Supplement digits 2 or 5 Truncation Expansion Truncate leading zeros The leading 0 digits of UPC A data characters can be truncated when the feature is enabled Expand to EAN 1...

Page 50: ...n Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Truncation Expansion None 00 Truncate leading zeros 01 Expand to EAN 13 02 Truncate system character 03 Add country code 04 ...

Page 51: ...Insertion group selection of 3 15 UPC A Supplement digits Format System character 0 Data digits 6 digits Check digit Supplement digits 2 or 5 Truncation Expansion Truncate leading zeros Refer to Truncation Expansion of 3 15 UPC A Expand to EAN 13 It extends to 13 digits with 0 digits when the feature is set to be enabled Example Barcode 0123654 Output 0012360000057 Expand to UPC A It extends to 12...

Page 52: ...n Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Truncation Expansion None 00 Truncate leading zeros 01 Expand to EAN 13 02 Expand to UPC A 03 Truncate system character 04 ...

Page 53: ...etting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Supplement digits Format System character 1 Data digits 5 digits Check digit Supplement digits 2 or 5 Truncation Expansion Expand to EAN 13 It extends to 13 digits with 0 digits when the feature is set to be enabled Expand to UPC A It extends to 12 digits when the feature is set to be enabled Truncate s...

Page 54: ...t verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Truncation Expansion None 00 Expand to EAN 13 02 Expand to UPC A 03 Truncate system character 04 ...

Page 55: ... to Insertion group selection of 3 15 UPC A Supplement digits Format Data digits 12 digits Check digit Supplement digits 2 or 5 ISBN ISSN conversion The ISBN International Standard Book Number or Bookland EAN and ISSN International Standard Serial Number are two kinds of barcode for books and magazines The ISBN is 10 digits with leading 978 and the ISSN is 8 digits with leading 977 of the EAN 13 s...

Page 56: ...rification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 EAN 13 code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 ISBN ISSN conversion Disable 00 Enable 01 ISBN ISSN code ID setting 00 FF16 ASCII 00 FF16 B ...

Page 57: ...he data digits Check digit trans By setting Enable check digit will be transmitted Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Supplement digits Format Data digits 7 digits Check digit Supplement Digits 2 or 5 Truncation Expansion Refer to Truncation Expansion of 3 15 UPC A ...

Page 58: ...1 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 C Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Truncation Expansion None 00 Truncate leading zero 01 Expand to EAN 13 02 ...

Page 59: ...length barcode decoded Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Start End transmission The start and end characters of Code 39 are s You can transmit all data digits including two s as data character By setting Enable can be recognized as data character Convert Code 39 to Code 32 Code 32 is a variant of Code 3...

Page 60: ...1 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 M Insert group selection 00 66 00 66 00 Format Standard 00 Full ASCII 01 Start End transmission Disable 00 Enable 01 as data character Disable 00 Enable 01 Convert Code 39 to Code 32 Disable 00 Enable 01 ...

Page 61: ... setting Single scan setting Option bar code Option Alpha entry Code 32 Prefix A transmission Disable 00 Enable 01 Trioptic Code 39 read Disable 00 Enable 01 Trioptic Code 39 Start End transmission Disable 00 Enable 01 ...

Page 62: ...ble check digit will be transmitted Max Min code length Refer to Max Min code length of 3 20 Code 39 Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 USS 01 OPCC 02 Check digit tra...

Page 63: ...o Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 00 Code ID setting 00 FF16 ASCII 00 FF16 H Insert group selection 00 66 00 66 00 ...

Page 64: ...the sum module 10 of the numerical values of all data digits Check digit transmission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 20 Code 39 Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A ...

Page 65: ...Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 06 Code ID setting 00 FF16 ASCII 00 FF16 X Insert group selection 00 66 00 66 00 ...

Page 66: ... Max Min code length Refer to Max Min code length of 3 20 Code 39 Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Start End type Codabar has four pairs of Start End pattern you may select one pair to match your application Start End transmission Refer to Start End transmission of 3 20 Code 39 Start End character equa...

Page 67: ...nable 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 00 Code ID setting 00 FF16 ASCII 00 FF16 N Insert group selection 00 66 00 66 00 Start End type ABCD ABCD 00 abcd abcd 01 ABCD TN E 02 abcd tn e 03 Start End transmission Disable 00 Enable 01 Start End character equality Disable 00 ...

Page 68: ...58 Multiple scan setting Single scan setting Option bar code Option Alpha entry Enable 01 ...

Page 69: ...ransmission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 20 Code 39 Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Truncate leading zeros The leading 0 digits of Code 128 barcode characters can be truncated when the feature is enabled ...

Page 70: ... Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Insert group selection 00 66 00 66 00 Truncate leading zeros Disable 00 All leading 0 s 01 Only the first 0 02 ...

Page 71: ...data digits Check digit transmission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 20 Code 39 Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Truncate leading zeros Refer to Truncate leading zeros of 3 25 Code 128 ...

Page 72: ... Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Insert group selection 00 66 00 66 00 Truncate leading zeros Disable 00 All leading 0 s 01 Only the first 0 02 ...

Page 73: ...gth of 3 20 Code 39 Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 ...

Page 74: ...Min code length of 3 20 Code 39 Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code len...

Page 75: ...de length Refer to Max Min code length of 3 20 Code 39 Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 One digit 01 Reserved 02 Reserved 03 Check digit transmission Disable 00 Ena...

Page 76: ... 2 will be transmitted upon your selected check digit verification method Max Min code length Refer to Max Min code length of 3 20 Code 39 Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 Check digit verification Dis...

Page 77: ... Max Min code length Refer to Max Min code length of 3 20 Code 39 Code ID setting Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 Max code ...

Page 78: ...ing Refer to Code ID setting of 3 15 UPC A Insertion group selection Refer to Insertion group selection of 3 15 UPC A Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 Max code length 00 99 00 99 11 Min code length 00 99 00 99 11 Code ID setting 00 FF16 ASCII 00 FF16 T Insert group selection 00 66 00 66 00 ...

Page 79: ...5 UPC A Conversion UCC EAN 128 Refer to Code ID transmission of 3 43 String transmission Cm will be identified as AIM ID UPC A or EAN 13 Barcode beginning with a single zero as the first digit has the leading 010 stripped and the barcode reported as EAN 13 Barcode beginning with two or more zeros but not six zeros has the leading 0100 stripped and the barcode reported as UPC A Multiple scan settin...

Page 80: ...Insertion group selection of 3 15 UPC A Conversion Refer to Conversion of 3 33 GS1 DataBar GS1 DataBar Truncated Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 R Insert group selection 00 66 00 66 00 Conversion None 00 UCC EAN 128 01 UPC A or EAN 13 02 ...

Page 81: ...C A Conversion UCC EAN 128 Refer to Code ID transmission of 3 43 String transmission Cm will be identified as AIM ID Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 R Insert group selection 00 66 00 66 00 Conversion None 00 UCC EAN 128 01 ...

Page 82: ...72 3 36 PDF417 Read Format Data characters variable Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 ...

Page 83: ...73 3 37 MicroPDF417 Read Format Data characters variable Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 ...

Page 84: ...74 3 38 QR Code Read Format Data characters variable Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 ...

Page 85: ...75 3 39 Data Matrix Read Format Data characters variable Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 ...

Page 86: ...76 3 40 Aztec Code Read Format Data characters variable Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01 ...

Page 87: ...dd a symbol of as a prefix for all symbols Steps 1 Scan the option barcode of Prefix string setting 2 Use the ASCII table to find the value of 24 3 Scan 2 and 4 from the barcode on the last page 4 Scan END barcode Scanning steps Scan the following barcodes in order Insert G1 G2 G3 G4 string setting The scanner offers 4 positions and 4 character strings to insert among the symbol Example Set G1 str...

Page 88: ... 2 3 4 5 6 Steps scan the following data in order Testing barcode Truncate ending G6 string setting By setting a defined ending character or string can be truncated Also a single character can be un defined Repeat of a G6 character setting While G5 is set as a single defined un defined character G6 can also be set to be repeated This setting is ignored when the truncate number is more than the bar...

Page 89: ...00 Postamble string setting 0 22 characters 00 FF16 None 00 Insert G1 string setting 0 22 characters 00 FF16 None 00 Insert G2 string setting 0 22 characters 00 FF16 None 00 Insert G3 string setting 0 22 characters 00 FF16 None 00 Insert G4 string setting 0 22 characters 00 FF16 None 00 FN1 substitution string setting 0 4 characters 00 FF16 SP 20 Truncate leading G5 string setting A un defined cha...

Page 90: ...d times 01 22 Un defined times All FF Truncate ending G6 string setting A un defined character 00 1 22 defined characters 01 7F16 0 30 Repeat of a G6 character setting Once 01 Defined times 01 22 Un defined times All FF Single character C1 replacement 0000 0000 0000 FFFF 16 Single character C2 replacement 0000 0000 0000 FFFF 16 ...

Page 91: ... insertion position is greater than the length of the symbol the insertion of string is not effective Code ID position It is allowed to select different positions of code ID placement Multiple scan setting Single scan setting Option bar code Option Alpha entry Insert G1 string position 00 99 00 99 00 Insert G2 string position 00 99 00 99 00 Insert G3 string position 00 99 00 99 00 Insert G4 string...

Page 92: ...be transmitted before the code data when Enable is selected The length is represented by a number with two digits Case conversion The characters within code data or the whole output string can be set in either upper case or lower case FN1 substitution transmission The scanner supports a FN1 substitution feature for keyboard wedge USB and RS 232 interface The replacement string of FN1 can be chosen...

Page 93: ...ransmission Disable 00 Enable 01 Preamble transmission Disable 00 Enable 01 Postamble transmission Disable 00 Enable 01 Code ID transmission Disable 00 Proprietary ID 01 AIM ID 02 Code length transmission Disable 00 Enable 01 Case conversion Disable 00 Upper data only 01 Lower data only 02 Upper whole string 03 Lower whole string 04 FN1 substitution transmission Disable 00 ...

Page 94: ...Alpha entry Keyboard wedge USB 01 RS 232 02 Keyboard wedge USB RS 232 03 All non printable character string transmission with string setting Disable 00 Enable 01 Transmit the first N data characters only All 99 01 99 Transmit the last N data characters only All 99 01 99 ...

Page 95: ...85 4 Test barcode symbols UPC A UPC E UPC E1 EAN 8 EAN 13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 Default setting Read disable Matrix 2 of 5 Code 93 ...

Page 96: ...86 UCC EAN 128 Code 11 Default setting Read disable MSI Plessey Default setting Read disable UK Plessey ISBN ISSN China Post GS1 DataBar GS1 DataBar Truncated GS1 DataBar Limited GS1 DataBar Expanded ...

Page 97: ...87 PDF417 12 890ab xyz MicroPDF417 0239 mdo QR code 1234567890ABCD XYZ Data Matrix 123890abc mdo ...

Page 98: ...88 Aztec Code 12345678901234567890 ...

Page 99: ...nning accuracy 1 Do not allow any abrasive material to touch the window 2 Remove any dirt particles with a damp cloth 3 Wipe the window using a tissue moistened with water 4 Do not spray water or other cleaning liquids directly into the window 5 Use a piece of soft and dry cloth when cleaning the scanner ...

Page 100: ...F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US Notes The 2nd and the 3rd columns above are used for keyboard wedge only H L 2 3 4 5 6 7 0 SP 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o DEL Example ASCII A 4...

Page 101: ...code is different 2 If using CODESOFT software firstly read the information through Help Index Code128 Special input syntax Also refer to ASCII table For example if we wish to make F1 barcode select Code128 then select CODE A type and input DC1 as data Up Down Left Right Page Up Page Down Backspace Tab Home End Enter Insert Delete F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Esc F11 F12 ...

Page 102: ...you wish to return all parameters of the cradle please scan the barcode above Turn off handheld unit If you wish to turn off the handheld unit please scan the barcode above If you want to turn on the handheld unit again please keep the trigger key being pressing for 2 seconds If you want to turn off the handheld unit via trigger key please press and hold the trigger key after the laser beam turns ...

Page 103: ...splay firmware version Cradle firmware version display If you wish to display the firmware version of the cradle please scan the barcode above Handheld unit firmware version display If you wish to display the firmware version of the handheld unit please scan the barcode above ...

Page 104: ...94 10 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below ...