31
AXOR Industries
Service Manual
Nano Mack
®
ver.1 rev.11/'19
2.6 Backup Supply connections
BACKUP SUPPLY
Notes
:
• Accepted voltage:
12
÷
24VDC
;
•
Max current required for the external supply:
0.1A
;
• We suggest to insert the
F
2
(
see cap. 1.3 Technical Data on page 11
1
F
2
2
External supply
12÷24V
DC
Nano Mack
CASE A
+ Bkup
AGND
J1
0V
+V
J1
1
F
2
2
External supply
12÷24V
DC
Nano Mack
+ Bkup
AGND
0V
+V
CASE B