F A U L T

C A U S E

R E M E D Y

⁄  Insufficient water

⁄  Supply pressure inadequate

⁄  Check water pressure (If a pump has been installed check 

to see if the pump is working).

⁄  Regulator filter dirty

⁄  Clean filter in front of the mixer and on the MTC-thermo car-

tridge

⁄  Shower filter seal dirty

⁄  Clean filter seal between shower and hose

⁄  Crossflow, hot water being forced into cold water pipe, or 

vice versa, when mixer is closed

⁄  Backflow preventers dirty or leaking

⁄  Clean backflow preventers, exchange if necessary

⁄  Spout temperature does not correspond with temperature 

set

⁄  Thermostat has not been adjusted

⁄  Adjust thermostat

⁄  Hot water temperature too low

⁄  Increase hot water temperature to 42 ºC to 65 ºC

⁄  Temperature regulation not possible

⁄  thermo cartridge calcified

⁄  Exchange thermo cartridge

⁄  Hot and cold supplies are reversed

⁄  change connections

⁄  Instantaneous heater didn't work with thermostat

⁄  Filters are dirty

⁄  Clean the filter ⁄ exchange filter

⁄  check valve hasn't moved back

⁄  Exchange check valves

⁄  Flow limiter in handshower isn’t removed

⁄  Remove flow limiter

⁄  Shower or spout dripping

⁄  Dirt or sedimentation on valve seat, shut-off unit damaged

⁄  Exchange shut-off unit

C L E A N I N G   (see page 10)

S P E C I A L   A C C E S S O R I E S   (order as an extra)
tile-matching-disk #93155000 (see page 12)

S P A R E   P A R T S   (see page 12)
XX = Colors
00 = chrome plated
93 = Polished Brass

F L O W   D I A G R A M   (see page 04)

 Hand shower

 overhead shower

D I M E N S I O N S   (see page 04)

O P E R A T I O N   (see page 09)

M A I N T E N A N C E

⁄  To guarantee the smooth running of the thermostat, it is necessary from 

time to time to turn the thermostat from total hot to total cold.

⁄  The mixer is equipped with check valves. The check valves must be 

checked regularly according to DIN EN 1717 in accordance with 
national or regional regulations (at least once a year).

A D J U S T M E N T   (see page 08)
After the installation, the output temperature of the thermostat must be 
checked. A correction is necessary if the temperature measured at the output 
differs from the temperature set on the thermostat.

Do not use silicone containing acetic acid!

S Y M B O L   D E S C R I P T I O N

 

S A F E T Y   N O T E S

 

Gloves should be worn during installation to prevent crushing and cutting injuries.

 

The shower system may only be used for bathing, hygienic and body cleaning 
purposes.

 

Children as well as adults with physical, mental and⁄or sensoric impairments must 
not use this product without proper supervision. Persons under the influence of 
alcohol or drugs are prohibited from using this product.

 

Do not allow the streams of the shower touch sensitive body parts (such as your 
eyes). An adequate distance must be kept between the shower and you.

 

The product may not be used as a holding handle. A separate handle must be 
installed.

 

The arm of the shower head is intended only to hold the shower head. Do not load 
it down with other objects!

 

The hot and cold supplies must be of equal pressures.

I N S T A L L A T I O N   I N S T R U C T I O N S

⁄  Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

⁄  The pipes and the fixture must be installed, flushed and tested as per the applicable 

standards.

⁄  The plumbing codes applicable in the respective countries must be oberserved.
⁄  The installation dimensions stated in these installation instructions are ideal for 

people of approximately 1700 mm in body height. The dimensions can be altered 
if required. In this case, pay attention to the fact that a change of installation height 
will also change the minimum height, and that the altered mounting dimensions must 
be taken into consideration.

⁄  During installation of the product by qualified trained personnel, make sure that the 

entire fastening surface is even and smooth (no protruding seams or tile offset), that 
the finish of the wall is suitable to apply the product and has no weak points.

⁄  The filter insert must be use to protect the shower against incoming dirt by 

pipework. Incoming dirt leads to defects or⁄and can damage parts of the shower; 
such caused faults voids all liability and guarantee claims.

⁄  The product is not designed to be used with steam baths!

EN

T E C H N I C A L   D A T A
Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

 

(1 MPa = 10 bar = 147 PSI)

Hot water temperature: 

max. 70°C

Recommended hot water temp.: 

65°C

Centre distance: 

150 mm

Connections G 1⁄2: 

cold right - hot left

Thermal disinfection: 

max. 70°C ⁄ 4 min

Safety against backflow
The product is exclusively designed for drinking water!

Summary of Contents for Showerpipe 27984007

Page 1: ...I N S T A L L A T I O N Z H 用户手册 组装说明 02 E N Instructions for use assembly instructions 03 AXOR Showerpipe 800 mm 27984007 27984937 ...

Page 2: ...安装完成后必须检查调温器的出水温度 如在取水处测量所得的温度 与调温器上设定的温度有偏差 那么必须进行调整 请勿使用含有乙酸的硅 符号说明 安全技巧 装配时为避免挤压和切割受伤 必须戴上手套 淋浴系统只允许作为洗浴 卫生和洁身之用 不得让儿童和肢体 精神和 或意识有障碍的成人在不受监管的情况下使用 淋浴系统 受酒精或毒品影响的人员不得使用淋浴系统 必须避免让身体敏感部位 如眼睛 接触到莲蓬头喷水 必须保持莲蓬头 与人头之间有足够的距离 该产品不得作扶柄使用 必须安装单独的扶柄 头顶花洒夹持杆只为夹持头顶花洒而设计 不得让其承载其它物品 冷热水管间过大的压力差必须予以平衡 安装提示 安装前必须检查产品是否受到运输损害 安装后将不认可运输损害或表面 损伤 管道和阀门必须根据通用标准进行安装 冲洗和检查 请遵守当地国家现行的安装规定 本安装说明中所规定的安装尺寸理想用于身高 1700 mm 左右...

Page 3: ...ould be worn during installation to prevent crushing and cutting injuries The shower system may only be used for bathing hygienic and body cleaning purposes Children as well as adults with physical mental and or sensoric impairments must not use this product without proper supervision Persons under the influence of alcohol or drugs are prohibited from using this product Do not allow the streams of...

Page 4: ... 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 2 1 1000 1100 900 2044 2144 1944 min 25 9 2 398 63 639 105 9 87 10 4 4 5 4 3 0 8 6 5 G 1 2 800 75 16 450 520 25 Ø 355 Ø 172 150 28 12 70 70 7 0 150 12 478 G1 2 713 9 2 398 63 639 105 9 87 10 4 4 5 4 3 0 8 6 5 G 1 2 800 75 16 450 520 25 Ø 355 Ø 172 150 28 12 0 4 ...

Page 5: ...0 5 SW 2 5 mm 9 12 7 10 1 1 2 2 3 8 11 Nr 10476220 Armaturenfett Grease 4 1 1 2 S i l i c o n e 2 1 2 X 34 mm X X 1 2 3 SW 27 mm 5 6 N r 1 0 4 7 6 2 2 0 A r m a t u r e n f e t t G r e a s e 34 2 ...

Page 6: ...0 6 60 mm Ø 6 mm 15 13 16 1 1 2 2 14 17 530 mm SW 3 mm 5 Nm SW 3 mm 1 5 Nm 18 SW 5 mm 21 19 22 20 23 1 2 1 2 1 2 24 ...

Page 7: ...0 7 60 mm Ø 6 mm SW 8 mm 27 25 28 26 29 SW 3 mm SW 3 mm SW 3 mm 30 33 31 34 32 35 ...

Page 8: ...0 8 1 2 3 ...

Page 9: ...更坚固 schwerer 更加简单 leichter 1 2 40 C 0 9 ...

Page 10: ...se damage Here too Carefully rinse with water after use to remove residues Likewise do not store any cleaning agents or chemicals under the products for example in a vanity unit as the vapours may damage the products The damage of already damaged surfaces will deteriorate under the effect of the cleansers COMPONENTS WITH DAMAGED SURFACES MUST BE EXCHANGED OTHERWISE THERE COULD BE AN INJURY DANGER ...

Page 11: ...11 1 2 3 4 10 mm max 10 min 10 min 5 6 20 mm max 10 min A B C D 1 min E F ...

Page 12: ...X0 1600 mm 96541001 92847000 96541001 98387000 17x2 5 98387000 17x2 5 98716000 96029000 96029000 98282000 93294000 98058000 98129000 14x2 95758000 98368000 93295000 93296000 98433000 30x1 5 92936000 32x1 5 96179000 96179000 95772000 95773000 98371000 29x3 96429000 98199000 17x2 98173000 22x1 5 93288XX0 98382000 12x2 5 AXOR Showerpipe 800 mm 27984007 27984937 93289XX0 93287XX0 93290000 ...

Reviews: