0 7
A S S E M B L Y (see page 60)
O P E R A T I O N (see page 63)
Hansgrohe recommends not to use as drinking water the first half litre flow-
ing from the tap in the morning, after the hygiene rinse is enabled, or after
prolonged non-use. The hygiene rinse opens the tap for 10 seconds every 24
hours following the last operation.
H Y G I E N E R I N S E
To enable or disable the hygiene rinse, proceed as follows:
⁄ Interrupt voltage supply of the fittings for approx. 10 s (disconnect electri-
cal plug connection between fittings and battery housing or power pack
and reconnect after 10 s)
⁄ The LED blinks to indicate the software version (e.g. blinking once =
software version 1)
⁄ permanent light from the LED indicates that calibration of the infrared
proximity electronics is in progress
⁄ wait for LED to go out
⁄ cover sensor window completely with your hand or a white piece of
paper
⁄ Remove your hand or the paper after 10 s
⁄ the currently enabled mode is indicated by the flashing of the LED: 1 x =
enabled, 2 x = disabled
P E R M A N E N T R I N S E
After setting the parameters for the hygiene rinse or making a net reset, wait
for approx. 100 s before you can enable the "Permanent rinse" function.
⁄ cover sensor window completely with your hand or a white piece of
paper
⁄ The tap opens briefly and then closes immediately. When the tap opens
again after approx. 5 s, remove the hand or the paper from the sight
glass.
⁄ Permanent rinse is enabled for 180 s and can be interrupted at any time
by a movement in the field of vision.
T H E R M A L D I S I N F E C T I O N
⁄ Thermal disinfection pursuant to process sheet DVGW W 551(≥ 70°C / >
3 min) must only be carried out by qualified personnel.
⁄ Risk of scalding with thermal disinfection!
⁄ The cold water feed must be locked during thermal disinfection. After-
wards, "Permanent rinse" can be enabled.
N E T R E S E T
A net reset causes the fittings to re-adjust
⁄ Interrupt the voltage supply to the fittings
⁄ Briefly reach into the field of vision of the fittings to cause the capacitor to
discharge
⁄ Wait for approx. 10 s, then plug the connectors in again
⁄ The fittings will re-adjust during the next 30 s. Do not reach into the field of
vision during this period of time.
E X C H A N G E B A T T E R Y (see page 64)
S A F E T Y F U N C T I O N (see page 61)
The desired maximum temperature for example max. 38ºC can be pre-set
thanks to the safety function.
M A I N T E N A N C E (see page 65)
The check valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
C L E A N I N G (see page 65) and enclosed brochure
Never use high pressure cleaners or steam cleaners to clean the fittings.
C L E A N I N G W A S H B A S I N (see page 64)
After setting the parameters for the hygiene rinse or making a net reset, wait
for approx. 90 s before you can enable the "Clean wash basin" function.
S P A R E P A R T S (see page 66)
F L O W D I A G R A M (see page 62)
with EcoSmart
®
3,8 l/ min
with EcoSmart
®
5,0 l/ min
D I M E N S I O N S (see page 62)
Do not use silicone containing acetic acid!
S Y M B O L D E S C R I P T I O N
EN
T E C H N I C A L D A T A
THIS MIXER SERIES-PRODUCED WITH ECOSMART
®
(flow limiter)
Operating pressure:
max. 0,8 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Maximum flowing-out temperature at 50 K temperature difference and 0,3 MPa flow
pressure:
approx. 42°C
Follow-on time:
1 - 2 sec.
Automatic switching-off:
after 10 sec.
battery:
CR-P2 / 6 V Lithium
transformer:
230 V AC ± 10 % / 50 – 60 Hz / 20 mA
Protection class:
IPX5
installation site of type plate:
see page 66
The product is exclusively designed for drinking water!
P R O T E C T E D A R E A (see page 60)
0, 1, 2
T E S T C E R T I F I C A T E (see page 62)