TROUBLE SHOOTING
Failure
Possible causes
Check Method
Counter measures
No nail
is ejected
Incorrect nails are loaded.
Abnormal nails are loaded (large
-
sized head ,bent
incorrectly chained, etc.)
Check if
recommended
nails are loaded
Use recommended nails
Remove abnormal nails and load
normal nails
Magazine Unit Push lever
Defective nail feeder (either bent
or broken)
Defective feed spring (worn or
broken)
Check for
abnormalities of
nail feeding
portion
(deflected, worn,
deformed broken)
Repair deformed parts
Replace defective parts
Narrow or wide width of the
Magazine groove
Worn nail head supporting
portion of Magazine
Abnormal nail guide groove
of Blade Guide (deflected,
deformed or broken)
Load nails and
confirm that they
will move
smoothly
No nail
is ejected
Adhesive fragment or wood dust
sticking on the Magazine or nail
feeder
Remove adhesive fragment or
wood dust
Push lever
Check push lever movement
Replace
[Output unit :Piston or driver]
Air pressure too low
Carry out idle driving and
check the return of the driver
blade
Check compressor
Worn piston ring
Replace piston ring
Defective piston bumper
Replace the piston bumper
Defective bumper piece (defective,
worn or broken)
Replace the piece
Defective O
-
ring (disconnected,
deformed or broken)
Reassamble or replace the o
-
ring
Defective driver blade, (deflected,
deformed or broken)
Replace
Defect inside cylinder (adhesive or
wood fragment, worn)
Check if the nailer drives at
minimum operating pressure
Remove adhesive fragment or wood dust