OPERATION
NOTE: The generator has been shipped without engine oil. fill with oil or it will not start.
1. Filling the Engine Oil (Fig.11)
SAE 10W-30 is recommended for general, all temperature use. Other viscosities shown in
the chart may be used when the average temperature in your area is within the indicated
range.
a) Remove the oil dipstick (9) and wipe the dipstick clean.
b) Check the oil level by inserting the dipstick into the filler neck without screwing it in,
c) If the level is low, fill to the upper limit of the oil filler neck with the recommended oil.
3. Start the engine
NOTE: Do not connect the electric load or equipment before starting the engine.
- Open the petrol cock (24) by turning it down.
- Move the ON/OFF switch (3) to position "I”.
- Move the choke lever (23) to position IØI. (if the engine has warmed up,then ignore this step).
- Start the engine with the grip of pull cord (26) by pulling the handle forcefully. If the
engine does not start, pull the handle again.
- Push the choke lever (23) back again after the engine has started.
IMPORTANT !
When starting with the pull cord, the motor may recoil suddenly as it starts up,
resulting in hand injuries. Wear protective gloves when starting the equipment.
WARNING: Once the generator has started, release the starting handle slowly
to avoid injury/damage as it whips back.
4. Connecting Electric Devices
- Ensure that electrical equipment is switched off before connecting to the generator.
IMPORTANT :
- These sockets may be loaded continuously (according rated power) and temporarily
(according max.power).
- Do not connect the generator to the domestic power network as this may result in
damage to the generator itself or to other electrical appliances in your home. Note:
Some electrical appliances (power jigsaws, drills, etc.) may have a higher level of power
consumption when used in difficult conditions.
CAUTION!
• Be sure the total load is within generator rated output.
• Be sure the socket load current is within socket rated current.
CAUTION!
• Make sure that the appliance being connected is in good working order, if it
begins to act abnormally or stops suddenly, disconnect it from the generator.
• Make sure the appliance does not exceed the maximum rated load for the generator.
• Any device with contains an inductive load e.g. devices that contain a motor may
require more current on startup.
CAUTION! Carefully pour in engine oil. Avoid spilling!
2. Filling the fuel
You must fill the fuel before start the engine.
- Open the fuel cap(2) (fig.12)
- Fill in fuel to the fuel tank,do not higher than the warning line of the fuel tank.
- Close the fuel cap(2)
fig.11
fig.12
102
101
|
GB