9
ASSEMBLY INSTRUCTIONS
5
6
5.Put the(A) burner cover on the burner.
6. Connect hose and regulator to cylinder.
The propane gas and cylinder are sold separately.
Use a standard 20 lb. propane cylinder only.
Use this heater only with a propane vapor withdrawal
supply system. See chapter 5 of the standard for
storage and handling of liquefied petroleum gas,
ANSI/NFPA 58. Your local library or fire department
should have this book.
Storage of an appliance indoors is permissible only if
the cylinder is disconnected and removed from the
appliance. A cylinder must be stored outdoors in a
well-ventilated area out of the reach of children. A
disconnected cylinder must have dust caps tightly
installed and must not be stored in a building, garage or
any other enclosed area. The maximum inlet gas supply
pressure: 250 psi, The minimum inlet gas supply
pressure: 5 psi.
The minimum hourly of 10000 Btu is the required input
rating for a heater for automatic operation at ratings less
than full input rating.
The pressure regulator and hose assembly supplied
with the appliance must be used.
The installation must conform with local codes, or in the
absence of local codes,with national fuel gas code,
ANSI Z223.1/NFPA54, natural gas and propane
Installation Code, CSA B149.1, or propane storage and
handling code, B149.2.
Standard 20 lb. tank