E
Place a steel washer over each bolt on
the burner top.
Lay reflector over the burner top bolts
add another steel washer to each bolt
and screw wing nuts to fasten reflector
to the burner.
F
Install a full gas cylinder on the base.
Connect the gas regulator hose to the QCC1 cylinder
valve by turning the knob clockwise manually.
Do not use a tool, tighten firmly by hand.
Replace cylinder cover.
LEAK TEST
Now that the heater is assembled, for your safety you must perform a leak test of all
connections and hoses.
Mix in a spray bottle equal parts of water and soap.
1. Ensure that the heater gas control knob is fully closed by turning
completely clockwise
2. Open cylinder valve.
3. Apply the solution generously to all connections and hoses.
If you detect bubbles, there is a leak. Close cylinder valve completely. Retighten the
leaking connection and repeat leak test process.
If the leak cannot be repaired permanently, close cylinder valve completely and contact
AZ patio heaters at 888-775-1330 or a qualified gas technician.
-4-