10015UK 01 -2004
Technical information:
ES-525 Validator
14
When the second photocell detects the coin,
its diameter measurement is complete.
The coin is being analysed by the ferrite coils
at the same time.
The coin pushes past the anti-return gate that
returns to its initial position to stop the coin
from returning.
If the coin is rejected, the acceptance gate
does not open and diverts the coin through
the rejection exit.
The solenoid activates the acceptance gate
for a valid coin.
If the coin is validated, the acceptance gate
opens.