10015UK 01 -2004
Technical information:
ES-525 Validator
16
Acceptance gate solenoid
3.
Introduce the tokens or coins to be programmed, (minimum advised is 25). The tokens or
coins will be accepted if they have been measured correctly.
4.
Remove the short on connector JP1. The
validator
indicates that it has been programmed
correctly by activating the acceptance gate solenoid for approximately 1 second. If there had
been any error in programming the
validator,
it would not activate the solenoid. If the
programming was carried out correctly, the
validator
can now accept the programmed tokens
or coins (it is not necessary to disconnect the
validator
).
To erase the programming of a token or coin, simply follow the same abovementioned
procedure
without
introducing any tokens or coins.
If there are a large number of tokens or coins rejected, re programme the
validator
with the rejected tokens or coins included in the set.
The auto programming function has been designed to programme any type of metallic
disk, whether it be a token or coin. The result obtained will be better the higher the
quality and uniformity of the tokens or coins used.
We recommend tokens or coins that are not magnetic, with a uniform dimension, alloy
and stamp and that do not have protrusions greater than the rim of the coin.
Summary of Contents for ES-525
Page 20: ...10015UK 01 2004 Technical information ES 525 Validator 19 CE...
Page 33: ...10015UK 01 2004 Technical information ES 525 Validator 32 CPU Sel ES525 UK...
Page 34: ...10015UK 01 2004 Technical information ES 525 Validator 33...
Page 40: ...10015UK 01 2004 Technical information ES 525 Validator 39...