10015UK 01 -2004
Technical information:
ES-525 Validator
5
x
Once the
validator
has checked that the inhibition line has been put to the selected
level for at least 1 millisecond, it deactivates the output lines and activates the
acceptance solenoid so the coin can pass the acceptance gate as a valid coin. It is at
this moment that the
validator
activates the sorter.
x
When the coin leaves the
validator
as a valid coin, it emits a code through the output
lines confirming that the coin has been accepted. The length of this code is
programmable between 1 and 255 milliseconds. The code that is sent is the same as
the first code sent. The inhibition line should have returned to inhibited state to be
ready for the introduction of the next coin. The maximum time between the first
signal and the confirmation signal is 1 second. If the acceptance process was correct
but for some reason the coin did not leave through the acceptance channel, the
validator
will not send the second code.
x
Second code.
C
1A
2B
D
E
F
G
M
O
N
R
Q
P
S
H
I
J
K
T
L
1
1
1
1
0
0
0
0
Figure 1 A.
Identification of the coin.
Figure 2 B.
Acceptance of the coin.
C.
Coin output signal.
D.
Inhibition.
E.
Acceptance gate.
F.
Sorter.
G.
Pins 2, 4, 6, 7, 9.
H.
Pin defined in the factory.
I.
Open.
J.
Closed.
K.
Activated.
L.
Deactivated.
M.
IS.
N.
Max. 1 sec.
O.
Min. 1 ms. / Max. 10 ms.
P.
1 ms.
Q.
Min. 1 ms.
R.
Min. 3 ms. / Max. 220 ms.
S.
1 – 255 ms.
T.
350 – 400 ms.
Ô
Changes in the output codes can be carried out as options.
Summary of Contents for ES-525
Page 20: ...10015UK 01 2004 Technical information ES 525 Validator 19 CE...
Page 33: ...10015UK 01 2004 Technical information ES 525 Validator 32 CPU Sel ES525 UK...
Page 34: ...10015UK 01 2004 Technical information ES 525 Validator 33...
Page 40: ...10015UK 01 2004 Technical information ES 525 Validator 39...