5
CAUTION
• Please consider the safety of patient fi rst and take care during the
product operating.
• Only qualifi ed person in dental surgery can be allowed to use the
product
• Please purchase the battery recommended by manufacturer and
take care of the usage manual of battery manufacturer before use
it for the product.
• Do not use the machine with the fi le which is bended, damaged,
deformed and/or not in ISO standard, otherwise, it might cause
injury by some possible fragments.
• Do not place or maintain the battery in the place in high temperature
such as the place exposed to direct sunlight, inside of a car in high
temperature or beside of stove and fi re and so on.
• Please take care of shaving, vibration, noise and heat of the product
before use and test by rotating naturally. Stop using the product if
condition of the product feels abnormal and contact a representa-
tive.
• Keep bur or fi le clean, otherwise dust might cause poor chucking
power and it may cause vibrations during operation. Users are re-
sponsible for operation, maintenance and inspection.
• Applications of machine is restricted by this manual and notrecom-
mended applications by a manufacturer should be avoided.
• An arbitrary use might cause users’ injury and loss of property and
the a manufacturer shall not be responsible for the results which
are made by the operation which is not mentioned in this manual.
• Keep the speed of the usage tool as recommend by tool manufactur-
er. Exceeding the speed limitation might cause an accident.
• Contact dealer when display shows wrong message, it might cause
an accident.
• Only recommended product and consumable parts by manufacturer
have to be used with the product, otherwise, it may cause an the
accident.
• Operating Condition
1) Temperature: 10°C ~ 30°C
2) Humidity: 10% ~ 80%
3) Atmospheric Pressure: 700 ~1,060hpa
• The temperature of the handpiece goes up to max. 41°C when
atmosphere temperature is 30°C.
• Before changing the head or fi le, turn off the power of the motor
handpiece. Changing it during power on may cause unintended ro-
tation by accidental activation of the ON/OFF button.
• When inserting the motor handpiece into the battery charger, posi-
tion the handpiece correctly. Pushing it into the charger forcibly in
the incorrect direction may cause damage.
• Take care not to put needle, pin into the charging terminal of the
battery charger.
• Place the motor handpiece into the charger after clean the liquid
or dust off. If the charging terminal is in dirty, it can be rusted and
cannot be charged properly.
• Do not lubricate the motor handpiece.
• Do not heat sterilize the motor handpiece. Do not autoclave the
motor handpeice.
• ELECTRIC SAFETY
In case of some faults in Electric Cord, Plug, and Connector, do not use
machine, otherwise it might cause Fire and Electric Shock. Do not pull
out the Plug with wet hand. Whenever the Plug to be pulled out, to be
sure to grasp the Plug body. Do not bend Electric Cord excessively. Do
not put heavy material onto Electric Cord.
- Never fail to use Outlet which is equipped with earth connection and
please be instructed the way how to install the earth connection from
manufacturer or technicians.
- Do not put several Plugs into one Outlet though multi-plug, which
might cause Fire and Electric Shock.
- Before use, please check if the control unit has set the gear ratio to
match with the gear ratio in the contra angle.
- If motor operating speed is too fast or stop during operation, contact
dealer.
- Take care not to drop or damage the motor and contra angle hand-
piece. Do not operate the product if product is not operating properly
after dropping on the fl oor or in water, instead contact the Head
offi ce or Dealer. That case may cause bur vibra- tion,excessive heat
and damage to the ball bearings.
• DISPOSAL
- When disposal of Control units, be sure to keep regulations which
stipulate disposal of industrial waste.
- When disposal of Motor and Handpiece, be sure to keep regulations
which stipulate disposal of medical waste.
- Used and fi nished battery is recommended to be returned to supplier.
The product use battery which is composed of Nickel Metal Hydride,
rechargeable, however, some countries stipulate it to be disposed
as special waste.
• INTENDED USE
BAE370R, BAE07, BAE05 and BAE03 are for indicated for use by den-
tists in standard endodontic procedures using rotary fi les and rotary
endodontic drills (Gates-Glidden)
BAE370R_IFU-Final.indd 5
02/04/2019 12:22:31
Summary of Contents for Optima E+
Page 2: ...2 BAE370R_IFU Final indd 2 02 04 2019 12 22 31...
Page 16: ...16 BAE370R_IFU Final indd 16 02 04 2019 12 22 34...
Page 30: ...30 BAE370R_IFU Final indd 30 02 04 2019 12 22 36...
Page 44: ...44 BAE370R_IFU Final indd 44 02 04 2019 12 22 39...
Page 58: ...58 BAE370R_IFU Final indd 58 02 04 2019 12 22 41...
Page 72: ...72 BAE370R_IFU Final indd 72 02 04 2019 12 22 44...
Page 86: ...86 NOTES BAE370R_IFU Final indd 86 02 04 2019 12 22 46...
Page 87: ...87 NOTES BAE370R_IFU Final indd 87 02 04 2019 12 22 46...