Read and save these instructions.
This instruction manual provides important
information concerning the use and care of the B-Air
Vantage 1500 Commercial Dehumidifier – Model VG
1500. Please read and follow these instructions in
order to ensure the safe operation and maximum
performance of your unit.
For any questions relating to the use and operation
of the unit, please contact: 877.800.2247 or email
info@b-air.com
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adaptor.
Use of an extension cord is not recommended
(see electrical safety section below)*.
Failure to follow these instructions can result in
death, fire, or electrical shock
.
Electrical Requirements
For 115V, 60Hz operation, a common grounded
outlet on a 15 amp circuit is required. If used in a
wet area, a ground fault interrupter (GFI) is required.
Built in Electrical Safety
For your safety and protection, this machine is
manufactured with a grounded plug on its power
cord. The power cord must be plugged into a
properly grounded receptacle. If a grounded
receptacle does not exist, have one installed by a
certified electrician. Do not cut or remove the
grounding prong on the power cord plug. We
recommend that this electrical circuit/receptacle
operate under a separate breaker or fuse.
*If use of an extension cord is unavoidable, it must
have a minimum of 12 AWG conductors if it is 25
feet long or less and 10 AWG conductors if it is
greater than 25 feet long.
Water Removal
The dehumidifier is equipped with an internal
condensate pump to remove the water that is
collected from the air. This allows the water to be
pumped 25 feet with the attached hose. For
emptying of the condensate pump for storage see
STORAGE section of this manual.
REQUIREMENTS FOR SAFE OPERATION
Never allow unauthorized individuals or children to
operate the unit at any time.
It is recommended that anyone operating the
VG 1500 wear the proper personal protective
equipment and follow safe work practices in
accordance with federal, state, provincial and
employer regulations.
Check condition of power cord(s) before using them.
Damaged cords can cause fatal electric shock
and/or equipment damage.
Power cord(s) should never be exposed to water,
heat, sharp, or abrasive objects; in addition, they
should never be kinked or crushed. Avoid tightly
wrapping the cords to prevent kinking of the internal
wires. Always replace damaged power cords
immediately.
Never pull the unit by the power cord.
Avoid running over power cords with utility
equipment and vehicles.
CAUTION: As with any piece of electrical
equipment, always make sure that the unit is
turned “OFF” prior to disconnecting it from an
electrical outlet. Failure to do so will cause
“arcing”, and could result in personal injury, fire
hazards and/or damage to the unit. Do not
disconnect the power cord from supply
receptacle while the unit is operating.
WARNING: To reduce risk of electrical shock, do
not expose this unit to water or rain – it is
certified for INDOOR USE ONLY. Do not touch
the electrical outlet or power cord(s) with wet
hands or while standing on a wet or damp
surface.
WARNING: Risk of electrical shock, or contact
with moving parts leading to personal injury or
death! Turn unit OFF and disconnect power cord
from supply receptacle before taking off any
removable covers.
WARNING: The dehumidifier will restart without
warning after a temporary power interruption. If
all covers are not in place, the intended
protection from the motorized impeller will not
be present - keep clear of the motorized impeller
to reduce the risk of injury.
WARNING: To reduce risk of fire or electrical
shock, do not use the AT450S with any solid-
state speed control device.
CAUTION: For general dehumidification use
only. Do not use to dehumidify hazardous or
explosive materials and vapors.