background image

Defrost Indicator 

The defrost indicator lamp will illuminate to indicate 
the dehumidifier is in defrost cycle.  During this 
period, the compressor is running and the system 
has reversed. 

 
 
Venting/Ducting

 

Exit air can be ducted on the dehumidifier.  Using 
ducting larger than 6.7” in diameter is 
recommended.  

 

 

Transporting 

The VG 1500 should be transported upright. When 
transporting the unit, there is the possibility of water 
spillage out of the pump reservoir or water drainage 
off of the wetted evaporator coil. It is therefore 
important to make effective use of the manual purge 
feature to evacuate the water out of the pump 
reservoir before moving the unit. After the OFF 
button has been depressed, it is recommended that 
a manual purge be initiated by depressing the 
PURGE button. Then wait at least 15 minutes for the 
water to shed off the evaporator and find its way into 
the pump reservoir. Initiate another manual purge to 
clear the pump reservoir of any residual water one 
last time before moving the unit. Disconnect and 
fully drain the drain hose before coiling it up. 

 
 
CAUTION: If the unit has been laid on its back, 
even for short periods of time, it must be set 
upright for at least ½ hour before being plugged 
in and started up. This gives the compressor oil 

and liquid refrigerant sufficient time to re-
distribute. Failure to do so can cause premature 
compressor failure, and voids the compressor 
warranty.

 

 
If extremely poor road conditions exist, or excessive 
shock and vibration are expected, take 
precautionary measures by padding the unit to 
provide impact absorption during transport. 
 

CAUTION: Always be careful when moving the 
dehumidifier inside a building or home.  Older 
structures with weakened floors and staircases 
may require special considerations for safe 
transport. 

 
 
 

MAINTENANCE 
 
Air Filter

 

Replacement frequency is very subjective, as it 
depends on the cleanliness of the job site air, as well 
the duration of use. The air filter should be checked 
regularly.  Operating the dehumidifier with a clogged 
filter will reduce efficiency. Operating it without a 
filter will cause the internal workings to become 
clogged allowing bacteria and mold to form. The unit 
can also accommodate a higher efficiency 
replacement filter of the same physical size and still 
operate effectively.  
 
 
 
 

 

Summary of Contents for VG 1500

Page 1: ...Model VG 1500 Industrial Dehumidifier Operating Instructions ...

Page 2: ...orized individuals or children to operate the unit at any time It is recommended that anyone operating the VG 1500 wear the proper personal protective equipment and follow safe work practices in accordance with federal state provincial and employer regulations Check condition of power cord s before using them Damaged cords can cause fatal electric shock and or equipment damage Power cord s should ...

Page 3: ...r otherwise serious injury or death could result The cover is required to be securely in place to allow proper operation for the safety overload and to act as a shield if the hermetic terminals blow out of the compressor shell OPERATION 1 Place dehumidifier inside area to be dried 2 Make sure all windows and doors are closed to the outside and seal off the wet area from any unaffected areas 3 Rout...

Page 4: ...drain hose before coiling it up CAUTION If the unit has been laid on its back even for short periods of time it must be set upright for at least hour before being plugged in and started up This gives the compressor oil and liquid refrigerant sufficient time to re distribute Failure to do so can cause premature compressor failure and voids the compressor warranty If extremely poor road conditions e...

Page 5: ...g if there are any leaks readjust the brackets STORAGE Freezing temperatures and biological growth must be considered before storing the dehumidifier The dehumidifier should be flushed with a bio fungicide before storing When storing the unit ensure that water has been removed from the reservoir and hose This will prevent damage caused by freezing temperatures and to prevent biological growth Use ...

Page 6: ...s not supplied by the manufacturer 7 Shipping damage or damage as a result of abuse in transporting the unit The manufacturer does not warrant that the goods sold are merchantable or fit for any particular purpose and makes no warranties other than as stated in this section All other warranties guaranties or representations express or implied by operation of law or otherwise are expressly disclaim...

Page 7: ...tomer failing which the effective date will be based upon the date of manufacture plus thirty 30 days Retain your bill of sale as proof of purchase For warranty information and assistance contact B Air and request the assistance of a technician at 877 800 2247 or email warranty b air com SPECIFICATIONS ...

Page 8: ...erein are for the guidance of qualified service personnel only Improper troubleshooting or servicing could result in fire shock explosion or mechanical injury hazards that can cause personal injury or death This troubleshooting guide is intended for use by qualified service personnel ...

Reviews: