LogBox-RHT-LCD
Temperature and Humidity Data Logger
0568 0038-01
0141 0315-88 29.11.2021
B+B Thermo-Technik GmbH | Heinrich-Hertz-Str. 4 | D-78166 Donaueschingen
Seite
10
von
18
Technische Änderungen vorbehalten
Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com
START MODE
•
Immediate Start
: Start as soon as set up is ready and sent (OK) to the device.
•
Date/Time
: Logs start at predefined date and time.
•
Setpoint
: Logs start when a certain temperature value is reached. In this option, the setpoint value is set in the
Channels
field, in the
Upper
Setpoint
and
Lower Setpoint
parameters (these options appear only when this log mode is selected)
•
Start Button
: Logging starts with pressing the
Button
•
Daily
: Logging starts every day at a predefined time
STOP MODE
•
Only Memory Mode:
when checked the memory mode is used to terminate the logging process
•
Date/time:
Logging stops at a predefined Date and time
•
Logs:
Logging stops after the execution of a predefined number of Logs
•
Daily:
Logging stops daily at a predefined time (to combine with Start Mode “
Daily
”
8.2.4
Finalization
CONFIGURATION
•
Send Configurations
: Allows you to send the configuration to the device.
•
Save to File
: Allows you to save the configuration to a file that can later be used.
•
Memory Download
: Allows you to download logs from memory.
Figure 15
Log register
Figure 16
Finalization