4
T
ECHNICAL
S
PECIFICATIONS
Feature
Description
Operating temperature
–40 °C to 70 °C
Sensor measure range
Temperature: –40.0 °C to 80.0 °C
Relative Humidity: 0.0 to 100.0 %RH, without condensation.
Dew Point: –40.0 °C to 100.0 °C
Accuracy
See Fig. 3.
A measure error can be compensated using the
OFFSET
parameter in the NXperience
or LogChart II software
Measurement resolutions
Temperature: 0.1 °C. 14 bits (16383 levels)
Relative Humidity: 0.1 %RH, 12 bits (4095 levels)
Response time
Temperature: up to 30 seconds with fairly still air.
Humidity: up to 8 seconds with fairly still air (20 to 80 %RH).
Memory capacity
32.000 (32 k) logs: Half for each channel or total when one of thechannels is not enabled
Measurement interval
1 second min. 18 hours max.
Supply
3.6 Vdc lithium battery (1/2 AA), built-in
Estimated autonomy
Higher than 200 days, with weekly data reading. Frequent logged data readings may shorten
battery life and the interval between acquisitions is too short.
Case
Polycarbonate
Protection
IP40
Dimensions
60 x 70 x 35 mm
Logger-PC data transfer time
According to the number of logs. 40 seconds
for 16.000 logs.
PC interface
Interface IR/USB or IR/Serial.
NXperience software
Operation environment
Configurator software for Windows ® 10, 8, 7, and XP.
Menus in Portugiese, English, French or Spanish.
Sets up, reads and displays data on the screen.
LogChart II software
Operation environment
Configurator software for Windows ® 10, 8, 7, and XP.
Menus in Portuguese, English, or Spanish.
Sets up, reads and displays data on the screen.
4.1
Measurement Accuracies
Figure 2
Logger Front 2