LogBox-RHT-LCD
Temperature and Humidity Data Logger
0568 0038-01
0141 0315-88 29.11.2021
B+B Thermo-Technik GmbH | Heinrich-Hertz-Str. 4 | D-78166 Donaueschingen
Seite
4
von
18
Technische Änderungen vorbehalten
Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com
5
O
PERATION
It is only possible to operate the device after the
NXperience
or
LogChart II
software are installed to a PC, according to the steps described in
the corresponding chapters of this manual.
The communication between logger and PC is performed with the use of the
IR-Link3
Interface.
The logger operation mode set up is defined in advance by using
NXprience
or
LogChart II
software. The configuration is sent to the logger
through the
IR-Link3
Interface.
The logger starts and stops logging as defined in the setup.
5.1
Registers Screens
5.1.1
Battery Saving Mode - IDLE
In the low battery consumption mode (IDLE), the register does not communicate. It always stays in this mode after
reset; register does not make acquisitions and does not update screen measures. For skipping IDLE mode, press
the
button for activating communication temporarily. After an acquisition configuration has been sent, it will
definitely be out of IDLE mode.
5.1.2
Main Screen
Indication screen for values measured by the register:
Figure 3
Mesurement Accuracies
Figure 4
IDLE Mode
Figure 6
Temperature and Dew Point
Figure 6
Temperature and Humidity