1.

 

FOREWORD 

 

Dear customer,  
 
We thank you for having purchased the 

Temperature Data Logger TagTemp

 and are very glad that you decided in favour of a 

product 

of B+B Thermo-Technik GmbH

. We hope this product will fully satify you and will assist you effectively in your work. 

This  Device  has  been  developped  to  be  technically  highly  up-to  date.  This  product  has  been  designed  in  accordance  with  the 
regnant  european  and  german  national  directives  and  rules.  For  a  proper  and  effective  usage  of  the  product  the  customer  shall 

observe  the  following  Operating  Instructions.  In  the  case  that  against  one’s  expectations  any  troubles  occure  which  you  can  not 
resolve  yourself,  please  contact  our  service  centers  or  your  salesperson.  We  go  after  giving  you  rapid  and  competent  help  to 

minimize the risk of long time outfalls. 
 
The following operating Instruction are an indispensable part of of this Product. It contains important advices for the starting up and 

further use of the device. 
 

2.

 

GENERAL INFORMATION 

This documentation contains informations which must be paid in attention to assure a highly effective and secure use of the supplied 
product  
 

Please read through the following instructions and make yourself familiar with the handling of the product before you insert it in your 
processes. Keep this document always readily to hand so you can consult it by need. 

 

2.1.

 

Labels 

Sign 

Meaning 

Notice 

 

Advice 

It  is  necessary  to  read  the  following  advices  before  beginning  the 
operations.  The  used  symbols  in  the  manual  acts  first  of  all  as  eye 
catcher for security risks. The symbols 

does not

 replace the security 

advices. 

The text must be read to the end.

   

 

 
 

Necessary to 

observe 

This  symbol  designate  important  advices  and  tips  that  are  necessary 
for the success of a workstep. They have to be followed in order to get 

good results. 

 

 

 

 

 

Summary of Contents for TagTemp

Page 1: ...gTemp Temperature Data Logger Technical changes reserved B B Thermo Technik GmbH Heinrich Hertz Str 4 D 78166 Donaueschingen 0141 0315 84 22 06 2016 Fon 49 771 83160 Fax 49 771 831650 info bb sensors com bb sensors com 1 14 ...

Page 2: ...ADVICE 4 4 WASTE AND DISPOSAL ADVICE 4 5 USAGE ACCORDING TO PURPOSE 4 6 PRODUCT DESCRIPTION 5 1 1 Supply voltage 5 6 2 Unpacking 5 6 3 Identification 5 7 OPERATION 6 7 1 Drivers and software installation 6 7 2 Running LogChart_II 7 7 3 Configuring the logger 8 8 DATA TRANSFER AND VISUALISATION 10 8 4 Offloading data 10 8 5 Visualizing data 10 8 6 Chart view 10 8 7 Sheet view 12 8 8 General informa...

Page 3: ... service centers or your salesperson We go after giving you rapid and competent help to minimize the risk of long time outfalls The following operating Instruction are an indispensable part of of this Product It contains important advices for the starting up and further use of the device 2 GENERAL INFORMATION This documentation contains informations which must be paid in attention to assure a high...

Page 4: ... W21 Caution agaist mobile engines W29 Caution against moving parts Electronic waste 3 SECURITY ADVICE The B B Therm Thechnik GmbH assumes no liability for damages occurred through failure to observe these security advices A usage non conforme to the instructions given in this manual can damage the device Body and property damages The use of the measurement system must be restricted to qualified p...

Page 5: ...ata logger TagTemp is a highly autonome temperature measurement device It is supplied with a built in 3 6 V lithium battery CR2032 6 2 Unpacking The following items must be included in the package The electronic logger TagTemp A CD ROM with the Logchart II software and a USB driver Quick logger operation guide The present operating instructions Optional a communication interface upon request 6 3 I...

Page 6: ...30 seconds of user inactivity To reactivate it press again the Start Stop Button The logger operation mode set up is defined in advance by using the LogChart II software Each setting must be defined and the consequences observed The logger starts and stops logging as defined in settings 7 1 Drivers and software installation In the Ir Link3 RS232 model there is a RSR232 Ir communication interface I...

Page 7: ...e same installation wizard will be displayed and you will have to select the option Install software automatically recommended as the driver may already be in the computer Logchart II Software installation Insert the supplied CD ROM in the CD drive of the PCs Laptop The software installlation wizzard will start automatically If it does not please run the LC_II_Setup exe program provided from your ...

Page 8: ...wnload the actual contents of the logger s memory Press to view online the 10 last logged values 7 3 Configuring the logger Make sure the communication interface is connected to the PC port selected The interface must be constantly directed towards the communication window on front part of the logger at a maximum distance of 0 5 m The logger must be first woken up by pressing once the Start Stop S...

Page 9: ... 1 second and the maximum is eighteen 18 hours Note When the type of value logged is maximum or minimum values see Value the minimum interval possible is 10 seconds Daily Operations Here the user defines the time at which daily logs will take place Estimated time This field informs the user how long it will take to fill totally the memory under the conditions set up during configuration Start of r...

Page 10: ...tion the minimum interval between measurements Period is 10 seconds Offset Gives the user the possibility to automatically correct the values logged Alarm Defines limit values that when exceeded characterize an alarm condition Alarm events are informed to the user through a flashing mode of the Alarm Indicator LED After filling all the fields select OK and settings will be sent to the logger Note ...

Page 11: ...Temp Temperature Data Logger Technical changes reserved B B Thermo Technik GmbH Heinrich Hertz Str 4 D 78166 Donaueschingen 0141 0315 84 22 06 2016 Fon 49 771 83160 Fax 49 771 831650 info bb sensors com bb sensors com 11 14 ...

Page 12: ...lar form press the icon Table View Values are presented in a tabular form listing the measurement time and value 8 8 General information sheet This window shows some information about the logger whose data were just read and its configuration The screen can be displayed by pressing the Parameter Viewing icon 8 9 Exporting data Logged data can be exported to different file formats for further analy...

Page 13: ...s correctly selected there are no other programs using the same port during the communication attempts there is no physical obstacle blocking the IR signal the cable is well connected to the PC the port selected does not present any problem 10 MAINTENANCE The housing can be cleaned with a wet cloth Do not use chemical solvents With the exception of exchanging empty batteries the logger is widely m...

Page 14: ...ions 30 x 47 x 0 47 mm Logger PC data transfer time According to the number of logs 40 seconds for 16 000 logs PC Interface Ir USB or Ir Serial LogChart ll software operation environment Set up Software for Windows 95 98 NT 2000 and XP Menus in Portuguese English or Spanish Sets up reads and displays data on the screen TagTemp 0568 0037 Data Logger for the record of up to 16 000 temperature values...

Reviews: