AirborneM2M™ User Guide
17
The location of the OEM reset button for the Enterprise devices is on the back of the enclosure, underneath
the label near the pigtail. The Industrial devices’ OEM reset button is on the Ethernet/Power end of the box
next to the 2.1mm barrel connector (See section 10.0.)
ENTERPRISE SERIAL INTERFACE JUMPERS
The Enterprise Serial Device Server supports RS-232/422/485 interface drivers, as well as power over pin
9. Selection of these options is made through both the web interface and hardware jumpers. Figure 7 shows
the interface selection jumpers for the different interface types.
Figure 7- Interface Selection Jumpers
The jumper selections must be made while the device is unpowered and before being used in the final
application.
The interface type selected by the interface jumpers in Figure 7 must match the
selected configuration for the
Configuration | Serial Port Settings | Serial
Interface Type
setting in the web interface.
INDICATOR LEDS
The devices provide indicator LEDs to provide feedback on the state of the device. These LEDs are a
useful tool during installation and troubleshooting.
Table 6 - Enterprise LED Indicators
LED
Color
Airborne Device State
POWER
Adapter is not powered.
Adapter failed Power On Self Test (POST) and is not configured for wireless
communication.
Adapter passed POST but is not configured for wireless network communication.
Adapter passed POST and is configured for wireless communication.
LINK
Adapter is not powered.
(Periodic Blinking) Adapter is searching for a valid network (Access Point) that
matches device’s configuration.
Adapter has successfully associated with an Access Point.
RS-485 w/
Termination
RS-232 Power Pin 9,
Cable Sense
1
1
RS-232
Cable Sense
1
RS-422 w/
Termination
1