IMediaChassis Series
6
Installing SNMP Management and Application (iMcV-) Modules
To install a module:
1. Remove the blank bracket (if present) covering the slot where the module
will be installed. B+B SmartWorx recommends installing blank brackets in
unused module slots.
2. Slide the module into the chassis using the card guides.
3. Secure the module to the chassis by tightening the captive screw. (Refer to
the documentation shipped with the module for configuration information.)
4. When installing modules observe ESD precautions, refer to the Electrostatic
Discharge Precautions section.
In order to manage an iMediaChassis series, the SNMP Management Module
needs to be installed in the appropriate slot of the chassis.
Install the iMediaChassis/20 SNMP Management Module into the first slot of the
chassis.
NOTE
This slot is ONLY for the Management Module; do not install Application Modules
such as media conversion and mode conversion modules in this slot.