I N S TA L L AT I O N P R O C E D U R E S
C. System Installation
1.
This system is designed to treat cold water,
therefore it must be installed before any heating
equipment or installed directly into the cold-water
line.
2.
Select a location which allows the BDC-6000BB
system to be in a vertical position with a mini-
mum of 6 inches (15 cm) unobstructed clearance
below the cartridge housings to allow cartridges
to be changed in the future. This system requires
about 6 – 8 inches (15 cm – 20.3 cm) horizontally
from the single stage bracket and housing to the
three-stage bracket and housings. The blue tubing
provided will be inserted into the outlet side of
the single stage housing and the inlet side of the
three-stage housings.
3.
Once proper location and height have been
determined, remove fi lter housings and cartridges
to make it easier to mount the bracket on the wall.
4.
Before attaching the brackets to the wall,
thread one black fi tting to the left-hand (inlet)
side of the three-stage bracket and housings.
Then thread the fi rst coupler to the outlet side of
the 3-stage bracket. Thread the fl ow meter to the
coupler. An arrow on the fl ow meter provides the
correct fl ow direction. Thread the second coupler
on the right-hand (outlet) side of the fl ow meter.
Lastly, thread the fl ow restrictor onto the open
coupler. Again, an arrow on the fl ow restrictor
provides the correct fl ow direction.
5.
Thread and tighten white fi ttings to each
side of the shut-off ball valve. Once the single
mounting bracket is placed over each opening of
the single stage housing, thread the shut off ball
valve on the left-hand side of the single housing
and bracket. Thread the fi rst black fi tting on the
right-hand (outlet) side of the single housing
and bracket. Thread the fi rst black fi tting on the
right-hand (outlet) side of the single housing and
bracket.
BDC3000BB
Nanotechnology Whole House Purifi cation System
6
Hel neu st 57
MINIMUM 6”
FLOOR
6”– 8”
MINIMUM 6”
FLOOR
6”– 8”
# 6001
FILTER
WHITE
FITTING
BALL VALVE
1”
WHITE
FITTING
MOUNTING
BRACKET
BLACK