background image

Put the device always on a stable and straight surface. Falling will damage the device.

The device must not be placed in direct sunlight or in places with high temperature. This will 

damage the device or shorten its lifespan.

Don‘t place it near heat sources like radiators or other heat producing devices.

Don‘t expose the device to water, moisture or high humidity.

Don‘t place it next to a sink or the bathroom. Avoid direct contact with water.

Don‘t try to open the device.

Prior to the first use of our product make a backup of your data.

In the case of improper use, we are not liable for any loss of data.

In any case, liability for loss of data is limited to the effort that is necessary to restore from 

existing backup copies.

User Manual 

EN

Safety Instructions

Network Cable Tester

Check for UTP, STP, and 

Modular Cables

Congratulations on the Purchase of WS001

Please read the manual and safety instructions before using the product for the first 

time. Otherwise damage may result.

According to the European WEEE directive, electrical and electronic equipment must not be disposed 

with consumers waste. Its components must be recycled or disposed apart from each other. Otherwise 

contaminative and hazardous substances can pollute our environment.

You as a consumer are committed by law to dispose electrical and electronic devices to the producer, 

the dealer, or public collecting points at the end of the devices lifetime for free. Particulars are regulated 

in national right. The symbol on the product, in the user‘s manual, or at the packaging alludes to these 

terms. With this kind of waste separation, application and waste disposal of used devices, you achieve 

an important share to environmental protection.
The CE Mark confirmed that this product meets the main requirements of the Directive 2014/30/EU 

of the European Parliament and the Council of Europe concerning telecommunications and terminal 

regarding the safety and health of users and of electro-magnetic interference compliance. 

The CE has been demonstrated. These statements are deposited by the manufacturer.

Instruction

· Test function for cables with RJ45, RJ12 and RJ11 plug

· Auto-Scan and step by step testing

· Test modes:

  Loop-back: for testing and localizing of laid network of communication cables

  Continuity: for continuity testing of network or communication cables

  Open: for localizing of disconnected single wires

  Shorts: locating of short-circuited single wires

  Miss-wire: identification of non-conform wire assignment

  Pin to pin configuration: 1 assignment testing

· Main device with one RJ45 female connector and one RJ11/12 female connector

· Remote unit with one RJ45 female connector and one RJ11/12 female connector

· Various LEDs for status display

· Operates with 9 Volt block battery (not included)

· Included a black zipper bag

Functions

Network Cable Tester can test RJ11,RJ12 and RJ45 cables to judge wrong connection, short 

circuit and open circuit.

Operation

1. Open the battery compartment at the back of the cable tester and insert a 9V battery (not 

included). Close the battery compartment and the tester is ready for use.

2. Switch the tester on (set it to „on“ for Automatic mode“ or to „S“ for the „Slow automatic       

    mode“.) The Power LED indicator will light up and flash as Figure 1.

    Switch on the tester:

    Off - Power Off

    On - Power On for Automatic Mode

    S - Slow for Slow Automatic Mode

3. Plug one end of the cable into the transmit connector of the main tester. Plug the other          

    end of the cable into the receiving connector of the Remote tester.

4. The wires will be now tested, one after another. The tester will switch from one wire to         

    the other automatically. Please refer to Figure 2. In this way the wiring can be quickly        

    checked on the display of the Remote terminator test outcome indicators.

    Main tester:  

1-2-3-4-5-6-7-8-G

    Remote tester:  

1-2-3-4-5-6-7-8-G (RJ45)

 

 

1-2-3-4-5-6 (RJ12)

 

 

1-2-3-4 (RJ11)

5. If the cable is wired in a wrong way, the test outcome indicators will ight up synchronously                     

    in the following sequence. Following are abnormal connections for reference: 

a) Open circuit on certain wire:

* Suppose wire No.3 is open circuited, neither of No.3 LED on the main tester nor on remote      

   tester would light up.

* If multiple wires are open circuited, all corresponding LED on the main tester and on         

   remote tester would not light up.

* If less than two wires are connected, none of the LED lights would light up.

b) Short Circuit:

* Suppose there are two wires short circuit between wire No.4 and wire No.5, both of LED    

   No.4 and No.5 of remote tester will light up weakly, while main tester unchanged.

* Suppose there are three wires short circuit between wire No.4, wire No.5 and wire No.6,  

   corresponding LED of remote tester would not light up while main tester unchanged.

* There is a simple way to test short circuit: connect one end to main tester, if No.4 and No.5  

   are light up, it means there‘s a short circuit between wire 4 and wire 5.

c) Wrong connection:

* If two ends of a cable are disordered, for example wire No.2 and No.4 mis-wired, then      

   displays on Main Tester will be   1-2-3-4-5-6-7-8-G

 

   Remote Tester will be 1-4-3-2-5-6-7-8-G

   So you can see wire 2 and wire 4 are mis-wired.

Warning

1. This cable tester can not test any electrified product.

2. 9V reduplicated battery is used in this tester. If any LED light appears weakly, please         

    change the battery.

3. Test can not be done while RJ45‘s Pin are not complety cromped well. Any disobeys may 

     lead to a permanent damage of the tester.

4. Please use high quality tools to crimp cables.

WARNING

This tester is not intended for use on powered circuits. Attaching this tester to a powered 

circuit can result in damage to the tester or injury to the user!

- Do not use this tester with its case open, or parts removed.

  Doing so may damage the tester and/or injure the user.

- When using this tester in schools and workshops, responsible teachers or skilled 

  personnel must control the usage of this tester. Failure to observe this precaution may      

  result in damage to the tester or injury to the user.

- Follow the recommendations of any Trade Organizations or Regulatory Agencies whose  

  scope encompasses the use of this tester. Failure to do so may result in damage to the  

  tester or injury to the user.

- Do not open this tester for maintenance without first disconnecting it from all eternal  

  circuitry. Failure to observe this precaution may result in damage to the tester or injury to  

  the user.

- Do not touch the ends of the cables when making tests. An unexpected dangerous 

  potential may be present. Failure to observe this precaution may result in damage to the 

  tester or injury to the user.

- Do not apply voltage or current to any of the tester‘s connectors. Doing so may damage     

  the tester and/or injure the user.

- This tester must not be used by children. Failure to observe this precaution may result in  

  damage to the tester or injury to the user.

- Do not use this tester to make measurements in adverse environments such as rain, snow,  

  fog or locations with steam, explosive gases or dust.

- Do not use the tester in condensing atmospheres. Do not use tester in conditions with  

  ambient temperature to avoid humidity and condensation of water inside the tester.

- Do not use this tester if it is wet, either from exposure to the weather or after cleaning the   

  case of the tester.

- Do not attempt immidiate use of the tester when bringin it from a cold environment to a 

  warm environment. Condensation of water inside and outside may produce dangerous  

  measuring conditions. Allow the tester to reach room temperature before using.

- Do not modify this tester. Changing the design could make the tester unsafe and this may      

  result in injury to the user.

- Do not use this tester if it has undergone long-term storage under unfavorable conditions.

- Do not use this tester if it has been damage in transport.

- Avoid usage near strong magnetic fields (magnets, loudspeakers, transformers, motors, 

  coils, relays, contactors, electromagnets, etc.) The tester may display readings that are in    

  error.

- Avoid usage near strong electrostatic field (high voltage power lines, television, computer  

  monitors, etc.) The tester may display readings that are in error.

- Avoid usage near strong RF fields (radio or television transmitters, walkie talkies, cellular   

  phones, etc.) The tester may display readings that are in error.

- Remove the battery when the tester may be left unused for longer than one month. 

  Chemical leakage from the battery could damage the tester.

- Do not use the tester if there is evidence of chemical leakage from the battery.

Networking tool set includes:

Crimping Tool for Modular 8P8C Plug

LSA Punchdown Tool

Stripping for Flat Communication cable

Test function for cables with RJ45, RJ12 and RJ11 Plug

WS001

Reviews: