& Low Voltage Halogen
LT™/ LT-L™/ LT-T™
Installation Instructions
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
B-K LIGHTING
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE
12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade
Optional
Stability Flange
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE
12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade
Optional
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE
12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade
Optional
Stability Flange
1. Loosen #8-32 stainless steel set screw on cap
using a 5/64” Allen wrench and remove.
THIS PRODUCT IS AVAILABLE WITH A FACTORY INSTALLED LED OR HALOGEN LAMP.
Halogen Lamp or LED Installation - If Required
DATE
11-30-16
REFERENCE
NUMBER
INS001109
3. Place cap on fixture and tighten set screw.
Tighten screw to 1/2 inch pounds. Top of
screw should sit flush with fixture cap.
Warning: Do not over tighten set screw.
Doing so will compromise O Ring seal and
will void warranty.
2. Install lamp. For BKSSL: Pull the heat sink
from the body to expose the LED board
and Driver components. Utilize quick
disconnects to change modular LED and
driver components. Re-install the heat sink
into body.
CAUTION…follow lamp manufacturers instructions. Do
not touch lamp glass with bare skin. High temperature
of lamp will cause skin oil to damage glass. Clean lamps
with alcohol, if touched.
Halogen
BKSSL
Integral Transformer
1. Pull branch circuit wires necessary for installation
(By Others) through Power Pipe™. Use waterproof
wire connectors (By Others) to connect transformer
primary leads to branch circuit wires. Connect
incoming ground to ground wire provided in
fixture body.
See wiring diagram.
120V
12V
Fixture
COM
Remote
Transformer
COM
120V
12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Optional
Stability Flange
120V
12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
2. Insert wires, connectors and/or transformer into
fixture base and attach to Power Pipe™. Tighten
three (3) #8-32 stainless steel round head Phillips
screws at base to secure.
120V
12V
Fixture
COM
Remote
Transformer
COM
120V
12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Optional
Stability Flange
120V
12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
120V
12V
Fixture
COM
Remote
Transformer
COM
120V
12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Optional
Stability Flange
120V
12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
WIRING DIAGRAM
Integral
Transformer
Fixed Stem And T-Housing Option Fixture Installation
TRANSFORMER HOUSING MUST BE INSTALLED ABOVE GRADE. POWER PIPE™ IS LABELED AT GRADE LEVEL.
TRANSFORMER HOUSING INSTALLED BELOW GRADE WILL VOID WARRANTY