background image

Finished grade

8 3/4”

2 window
faceplate 
shown

Finished grade

8 3/4”

LINE

12V

FIXTURE

COM

Remote

Transformer

COM

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Finished grade

Concrete

Wire nuts must 

clear opening

6” 

min.

Finished grade

8 3/4”

2 window
faceplate 
shown

Finished grade

8 3/4”

LINE

12V

FIXTURE

COM

Remote

Transformer

COM

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Finished grade

Concrete

Wire nuts must 

clear opening

6” 

min.

9.  Remove temporary cover and pull out low 

voltage wire.

Finished grade

8 3/4”

2 window
faceplate 
shown

Finished grade

8 3/4”

LINE

12V

FIXTURE

COM

Remote

Transformer

COM

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Finished grade

Concrete

Wire nuts must 

clear opening

6” 

min.

11.  Mount faceplate to collar using (2) #6-32 screws 

(provided) with a 5/64” Allen wrench.

WIRING DIAGRAM

 LED - For use with 12VAC LED remote 

transformer or magnetic transformers only. 

B-K Lighting cannot guarantee performance 

with third party manufacturers’ 

transformers.

Finished grade

8 3/4”

2 window
faceplate 
shown

Finished grade

8 3/4”

LINE

12V

FIXTURE

COM

Remote

Transformer

COM

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Finished grade

Concrete

Wire nuts must 

clear opening

6” 

min.

8. 

 

Fill the hole around the fixture housing to 12” 

below the finished grade with clean fill dirt and 

tamp carefully to prevent settling of fixture. 

Pour concrete and finish as required flush with 

mounting collar.

 

NOTE: The mounting collar must be flush to 

finished grade. Use stability flange to aid in 

installation as shown.

Dia.

(56mm)

(32mm)

1 1/4"

(191mm)

7 1/2"

2 1/4"

8 3/4"

(222mm)

(42mm)

1 5/8" Dia.

(56mm)

8 3/4"

(222mm)

(32mm)

1 1/4"

Dia.

2 1/4"

7 1/2"

(191mm)

(42mm)

1 5/8" Dia.

6" Dia.

 (152mm)

2 1/4" Dia.

(57mm)

1 1/2" O.C.

(38mm)

7/8"

 (152mm)

 (22mm)

Concrete

Pour Collar

5’ 

(1524mm) 

 18 Ga. 

2 low voltage 

direct burial 

 cable

MINI-MICRO™ RECESSED UPLIGHT

Flush Mount Installation

RELEASE DATE

11/02/2021

REFERENCE NUMBER

INS000933

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • info@bklighting.com

B-K LIGHTING

Finished grade

8 3/4”

2 window
faceplate 
shown

Finished grade

8 3/4”

LINE

12V

FIXTURE

COM

Remote

Transformer

COM

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Finished grade

Concrete

Wire nuts must 

clear opening

6” 

min.

10.  Access low voltage wire inside Power Pipe™. 

Make two watertight connections using 

waterproof wire connectors (By Others). Wire 

nuts must clear opening. Insert fixture and 

low voltage wire into housing. 

See wiring 

diagram.

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS