background image

Power Meter in Watt and dB

Power Meter in Watt and dB

The Stereo Power Meter displays the output power in Watt at 4-Ohm speakers, and 
in dB relative to 1 Watt.

Since these electro-mechanical instruments are innately too slow for music pulses, 
an electronic circuit analyzes the signals at the speaker output and memorizes the 
result until the needle has been able to display it.

The dB level indicator refers to 0dB = 1 Watt.

Decibels (dB) is related logarithmically to power in the following way:

-30dB = one thousandth of the power

-20dB = one hundredth of the power

-10 dB = one tenth of the power

-6dB = a quarter of the power

-3 dB = half the power

+3 dB = twice the power

+6 dB = fourfold the power 

+10 dB = tenfold the power

+20 dB = hundredfold the power

+26 dB = fourhundredfold the power

+30 dB = thousandfold the power

Congratulations on the purchase of this exceptional LEF-power amplifier! We would 
like to say thank you to support our concept of a very short signal path, for there is the 
advantage of being able to select just the required gain. 

B.M.C.’s CS2 volume control DIGM = Discrete Intelligent Gain Management avoids 
both unnecessary high gain and additional amplifier stages, as well as attenuating the 
input signal, as it is done in traditional solutions. The gain required for the desired 
sound level is set in the amplifier stage.

The great power supply with 2kW toroid transformer, Balanced-Current Capacitors 
and  complete  stabilization,  for  the  power  section  as  well,  is  designed  unusually 
extensive and lavish. This is the ideal base for a silent background and for playing the 
very finest detail, as well as explosive dynamics.

CS2 offers 3 different Operating Modes

1:  The classical integrated Amplifier mode, with the volume controlled at the unit - or 
at the remote control RC1. The volume is managed by DIGM and the CI mode (current 
injection) can manually be activated for any XLR input by holding the input key for 5 
seconds.  CI  mode  is  recommended  only  for  connected  B.M.C.  components  like 
BDCD1.1 or the MCCI phono stage.

2:  The  classical  Power  Amplifier  mode,  with  volume  controlled  by  a  preamplifier. 
There  is  still  the  advantage  of  a  gain  presetting  by  DIGM,  may  be  for  better 
signal/noise ratio, adjustment of channels for home cinema use, or matching the CS2 
to a mixing console of a recording or mastering studio. Due to the numeric display the 
preference gain can be set easily again after an new amplifier power-on.

3:  In a consistent B.M.C. Audio chain with an OPTO CONTROL connection DIGM can 
be set by the B.M.C. DAC. The DIGM function will be same to the Amplifier mode (1), 
with  the  difference  of  where  to  turn  the  Volume  knob.  The  big  advantage  of  this 
operating mode is: You can use any balanced input in CI (Current Injection) mode with 
it's audiophile advantage of an advanced and exceptional signal path.

Summary of Contents for CS2

Page 1: ...EN Power turn Dimmer Input Volume Input Indicator DIGM display Power Meter B M C Audio CS2 Quick Start Guide B M C Audio CS2 Owner s Manual The CS2 is as easy to use as any amplifier Connect the AC po...

Page 2: ...lay DIGM Volume Adjustment and Display Remote Control Troubleshooting Maintainance Service Important Safety Information General Safety Precautions CE FCC declaration Recycling Content of Packing Power...

Page 3: ...he amplifier stage The great power supply with 2kW toroid transformer Balanced Current Capacitors and complete stabilization for the power section as well is designed unusually extensive and lavish Th...

Page 4: ...edure again to disable CI for the selected XLR input Note Never use CI inputs for non B M C components In most cases the sound quality will decrease due to incompatibility and in some cases even a dam...

Page 5: ...ith the instructions may cause interference to radio communications There is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferenc...

Page 6: ...ask an electrician to replace such outdated wall outlet 10 Protect the unit s power cord from being walked on or pinched especially around the plugs convenience receptacles and where it exits the unit...

Page 7: ...ers We recommend using DIGM 66 only if required A lower DIGM setting compensates by better sound quality At DIGM 00 the input is switched off for a complete mute Explanation of the used symbols The li...

Page 8: ...ower cable is connected at both sides Make sure there is AC power available at the wall outlet Check the power switch position ERROR displayed An internal error occurred Please switch off the unit wai...