Installation Instructions
JAMISON DOOR COMPANY
12
H4494002 REV B
•
Measure between the black tracks at four (4) different elevations. The distance must be the
same at all four elevations.
A=B=C=D
•
Install fasteners into the mounting slots within the Column Assemblies, slots near the motor
bracket, slots near the counterweight pulley, and the angle brackets by the transmission tube
unions.
•
Verify distance between tracks did not change. Install floor anchors.
•
Remove the lifting spacer bar from the back of the bearing plates and install the last spacer bar
(match color dots).
•
If center bearing was provided, assemble to center of transmission shaft assembly and the wall.
A
B
C
D
NOTE: Replace lifting
spacer bar with spacer
bar after the columns
are anchored in place.
Assemble the center bearing assembly (if
provided) to the center of the transmission
shaft assembly and the wall.