EXTERNAL THERMOSTAT TURNING
OFF TIME
Waiting time in order to turn off with external thermostat
The option “External Thermostat enabling” on TECHNICAL
PARAMETERS has to be activated
If it’s 00, the burner remain in modulation modality without
stopping (power 1)
W
hen it’s between 1 and 99, indicates the waiting time
(minutes) before stop
When it finishes to turn off, automatically restarts although the
external thermostat remains open
If
“Delta Temperature Waiting Time” is set to 0, it doesn’t restart
until the contact is closed.
Normally: 00 minutes