background image

14

Subject to change without prior notice

EN

This product falls within the scope of Directive 2012/19/EU on the management of waste electrical and electronic equipment (WEEE). 
The appliance should not be disposed of with household waste as it is composed of different materials that can be recycled at the 
appropriate facilities. Inquire through the municipal authority regarding the location of the ecological platforms suitable for receiving 
the product for  disposal and its subsequent correct recycling. The product is not potentially dangerous to human health and the 
environment, but if abandoned in the environment it negatively impacts the ecosystem. The symbol of the crossed-out bin, present 
on the label placed on the appliance, indicates the compliance of this product with the legislation on waste electrical and electronic 
equipment.

12.  Information for the correct disposal of the product

The abandonment of the equipment in the environment or the abusive disposal of the same are punishable by law.

B METERS srl 

Via Friuli, 3 • Gonars 33050 (UD) • ITALY

E-mail (sales/info): info@bmeters.com
E-mail (support): ticket@bmeters.com
Web: 

www.bmeters.com

Tel: +39 0432 931415
Tel: +39 0432 1690412
Fax: +39 0432 992661

For the complete manual,
please refer to the product
page on our website →

Summary of Contents for HYDROCAL-M4

Page 1: ...ons in this manual For further technical clarification please contact Customer Service Installation should be carried out exclusively by qualified personnel The reference standard for the instrument i...

Page 2: ...Remove the device from the package only at the time of installation to protect it from damage and dirt The air transport of active radio devices is prohibited Carefully observe the instructions in the...

Page 3: ...areas protected against impacts If the protective casing breaks contact customer service The display turns off To activate it press the button on the device The display remains active for 60 seconds T...

Page 4: ...elines and directives B METERS disclaim all liability for consequential damage resulting from the use of third party gaskets such as corrosion of sealing surfaces and threads Problem Cause Solution Di...

Page 5: ...the arrow in relief on the brass body and respecting the prescribed position To ensure proper measurement make sure that there is no air inside the pipe and that the flow is clean and free of debris p...

Page 6: ...ly probe must be installed in a ball valve or in a socket mounted on the flow pipe and complies with the requirements of the sensor itself Vice versa the version for installation on the inlet pipe the...

Page 7: ...3 Heating data index 4 Cooling data index 5 Circuit 1 2 pulse emitter external module 6 Return temperature index 7 Indicator of sub level presence 8 Supply temperature index 9 Battery level indicator...

Page 8: ...s T2 button 2 Units of measurement set Unit select through the left right button T1 T2 one of the following items 1 Joule 2 MJ 3 GJ 4 kWh 5 MWh Holding down the right button for 3 seconds can temporar...

Page 9: ...pressing the T1 button you can choose the desired level while pressing the T2 button you can view the sublevels of the preset level After 60 seconds without iteration the display turns off If no butt...

Page 10: ...IN 2 Type of pulse 4 02 MEMORY DAY 2 4 02 1 HEAT J MJ GJ kWh MWh 4 02 2 COOL J MJ GJ kWh MWh 4 02 3 IN 1 Type of pulse 4 02 4 IN 2 Type of pulse 6 INDEX INF UM 6 xx MONTLY MEMORY 1 6 xx 1 HEAT J MJ GJ...

Page 11: ...rrors and faults When one or more anomalies occur the thermal energy meter will report the recorded error and show the following icon on the display If the NFC or IR interface is used the icon will bl...

Page 12: ...n be activated and further details on the thermal energy meter refer to the complete User manual available at www bmeters com 10 Battery and replacement procedures The thermal energy meter constantly...

Page 13: ...asuring temperature range cooling 0 2 C 90 C Temperature range difference cooling 0 2 K 90K Counting operating conditions start Heating 1K counting enabling conditions Cooling 0 2K Max measurable powe...

Page 14: ...angerous to human health and the environment but if abandoned in the environment it negatively impacts the ecosystem The symbol of the crossed out bin present on the label placed on the appliance indi...

Reviews: