background image

4

Subject to change without prior notice

EN

Rinse the pipes thoroughly before installing the meter.

The device must be installed pay attention to matching the direction of the arrow on the meter 
brass body to the direction of the flow.

Avoid collecting air bubbles in the meter during the installation process.

The thermal energy meter must not be subjected to mechanical stress when installed in the 
pipeline.

The meter must be installed in such a way as to be protected from all impurities and external 
contamination.

Manually and simultaneously screw the device fittings on both sides, and then tighten in opposi-
te directions using a suitable device.

Remove old seals and clean the sealing surfaces.

Slightly grease the sealing surfaces (use grease approved by MID Standards).

Mount only the newly supplied gaskets (gaskets should not get in the pipeline). Seals provided 
on site must be fit for purpose and comply with local guidelines and directives. B METERS 
disclaim all liability for consequential damage resulting from the use of third-party gaskets, such 
as corrosion of sealing surfaces and threads.

Problem

Cause

Solution

Display off, pressing buttons does 
not respond

The battery may be damaged or discharged

Inform Customer Service

Damaged brass case or leakage

Possible external impact or fall to the ground

Inform Customer Service

Lower case brass separated
by electronic unit

Tampering by third party or strong external 
impacts

Inform Customer Service

Open and visible electronic unit

Tampering by third party or strong external 
impacts

Inform Customer Service

No consumption is accounted

Tampering by third party, strong external shocks 
or damage to the flow detection sensor

Inform Customer Service

Error 12 always present

Damaged temperature probes

Inform Customer Service

Error 18 or 19 always present

Damaged temperature probes or out of system 
temperatures limits

Inform Customer Service

Does not transmit via radio

Failure to pass 5 absolute liters or the batteries 
may be damaged or discharged

Inform Customer Service

TROUBLESHOOTING

Summary of Contents for HYDROCAL-M4

Page 1: ...ons in this manual For further technical clarification please contact Customer Service Installation should be carried out exclusively by qualified personnel The reference standard for the instrument i...

Page 2: ...Remove the device from the package only at the time of installation to protect it from damage and dirt The air transport of active radio devices is prohibited Carefully observe the instructions in the...

Page 3: ...areas protected against impacts If the protective casing breaks contact customer service The display turns off To activate it press the button on the device The display remains active for 60 seconds T...

Page 4: ...elines and directives B METERS disclaim all liability for consequential damage resulting from the use of third party gaskets such as corrosion of sealing surfaces and threads Problem Cause Solution Di...

Page 5: ...the arrow in relief on the brass body and respecting the prescribed position To ensure proper measurement make sure that there is no air inside the pipe and that the flow is clean and free of debris p...

Page 6: ...ly probe must be installed in a ball valve or in a socket mounted on the flow pipe and complies with the requirements of the sensor itself Vice versa the version for installation on the inlet pipe the...

Page 7: ...3 Heating data index 4 Cooling data index 5 Circuit 1 2 pulse emitter external module 6 Return temperature index 7 Indicator of sub level presence 8 Supply temperature index 9 Battery level indicator...

Page 8: ...s T2 button 2 Units of measurement set Unit select through the left right button T1 T2 one of the following items 1 Joule 2 MJ 3 GJ 4 kWh 5 MWh Holding down the right button for 3 seconds can temporar...

Page 9: ...pressing the T1 button you can choose the desired level while pressing the T2 button you can view the sublevels of the preset level After 60 seconds without iteration the display turns off If no butt...

Page 10: ...IN 2 Type of pulse 4 02 MEMORY DAY 2 4 02 1 HEAT J MJ GJ kWh MWh 4 02 2 COOL J MJ GJ kWh MWh 4 02 3 IN 1 Type of pulse 4 02 4 IN 2 Type of pulse 6 INDEX INF UM 6 xx MONTLY MEMORY 1 6 xx 1 HEAT J MJ GJ...

Page 11: ...rrors and faults When one or more anomalies occur the thermal energy meter will report the recorded error and show the following icon on the display If the NFC or IR interface is used the icon will bl...

Page 12: ...n be activated and further details on the thermal energy meter refer to the complete User manual available at www bmeters com 10 Battery and replacement procedures The thermal energy meter constantly...

Page 13: ...asuring temperature range cooling 0 2 C 90 C Temperature range difference cooling 0 2 K 90K Counting operating conditions start Heating 1K counting enabling conditions Cooling 0 2K Max measurable powe...

Page 14: ...angerous to human health and the environment but if abandoned in the environment it negatively impacts the ecosystem The symbol of the crossed out bin present on the label placed on the appliance indi...

Reviews: