background image

8

Subject to change without prior notice

EN

1.  Installation version (

set Mode

): select, through the left/right button (T1/T2), the type of installation 

(supply or return). Holding down the right button for 3 seconds can temporarily confirm the choice 
made by switching to level 2 (unit of measurement). If the T1 button is pressed for 3 seconds the 
device will return to stock mode showing ‘SLEEP’ on display.

6. Commissioning

Premise: before a functional tests, the procedures indicated in this paragraph must be performed for 
completing the physical installation phases including the connections.

If the activation takes place with buttons, the items in the menu will be two:

Long press

T2 button

or

Set mode

with both 

buttons

Set unit

with both 

buttons

or

or

or

or

Long press

T2 button

Long press

T2 button

Long press

T2 button

2.  Units of measurement (

set Unit

): select through the left/right button (T1/T2), one of the following 

items: 1 (Joule), 2 (MJ), 3 (GJ), 4 (kWh), 5 (MWh). 
Holding down the right button for 3 seconds can temporarily confirm the choice made by switching 
to level 2 (unit of measurement). If the T1 button is pressed for 3 seconds the device will return to 
stock mode showing ‘set Mode’ on display.

NOTE

: after confirmation the thermal energy meter will perform the initialization for heating and 

cooling accounting. The unit of measurement can be changed later via NFC.

INITIALIZATION (Installation version and measuring unit already configured)

The first configuration chosen during installation (supply or return pipe) can’t be modified!

Press T2 button for three seconds to initialize the device, if the installation version and the unit of measurement 
have already been configured as requested during the order.

The device is delivered in sleep mode and it must be configured if not requested during the order.

x=1

x=2

1

2

Summary of Contents for HYDROCAL-M4

Page 1: ...ons in this manual For further technical clarification please contact Customer Service Installation should be carried out exclusively by qualified personnel The reference standard for the instrument i...

Page 2: ...Remove the device from the package only at the time of installation to protect it from damage and dirt The air transport of active radio devices is prohibited Carefully observe the instructions in the...

Page 3: ...areas protected against impacts If the protective casing breaks contact customer service The display turns off To activate it press the button on the device The display remains active for 60 seconds T...

Page 4: ...elines and directives B METERS disclaim all liability for consequential damage resulting from the use of third party gaskets such as corrosion of sealing surfaces and threads Problem Cause Solution Di...

Page 5: ...the arrow in relief on the brass body and respecting the prescribed position To ensure proper measurement make sure that there is no air inside the pipe and that the flow is clean and free of debris p...

Page 6: ...ly probe must be installed in a ball valve or in a socket mounted on the flow pipe and complies with the requirements of the sensor itself Vice versa the version for installation on the inlet pipe the...

Page 7: ...3 Heating data index 4 Cooling data index 5 Circuit 1 2 pulse emitter external module 6 Return temperature index 7 Indicator of sub level presence 8 Supply temperature index 9 Battery level indicator...

Page 8: ...s T2 button 2 Units of measurement set Unit select through the left right button T1 T2 one of the following items 1 Joule 2 MJ 3 GJ 4 kWh 5 MWh Holding down the right button for 3 seconds can temporar...

Page 9: ...pressing the T1 button you can choose the desired level while pressing the T2 button you can view the sublevels of the preset level After 60 seconds without iteration the display turns off If no butt...

Page 10: ...IN 2 Type of pulse 4 02 MEMORY DAY 2 4 02 1 HEAT J MJ GJ kWh MWh 4 02 2 COOL J MJ GJ kWh MWh 4 02 3 IN 1 Type of pulse 4 02 4 IN 2 Type of pulse 6 INDEX INF UM 6 xx MONTLY MEMORY 1 6 xx 1 HEAT J MJ GJ...

Page 11: ...rrors and faults When one or more anomalies occur the thermal energy meter will report the recorded error and show the following icon on the display If the NFC or IR interface is used the icon will bl...

Page 12: ...n be activated and further details on the thermal energy meter refer to the complete User manual available at www bmeters com 10 Battery and replacement procedures The thermal energy meter constantly...

Page 13: ...asuring temperature range cooling 0 2 C 90 C Temperature range difference cooling 0 2 K 90K Counting operating conditions start Heating 1K counting enabling conditions Cooling 0 2K Max measurable powe...

Page 14: ...angerous to human health and the environment but if abandoned in the environment it negatively impacts the ecosystem The symbol of the crossed out bin present on the label placed on the appliance indi...

Reviews: