HYDROCLIMA 2 - User Manual
Installation of a heating cost allocator with remote sensor
Installation on towel warmers
The installation of the Hydroclima 2 allocator with a remote sensor is shown in the figures below. The cost allocator
should be mounted on the wall at a height of 1.5 meters. The heat sink with the sensor is mounted with the handle
at the level of 75% of the height and 50% of the width of the radiator, any deviations from the assumed mounting
position are the same as described in section “Installation” point 2.
The allocator (heat sink) should be installed at 75% of the radiator’s height, on the opposite collector from the power
supply, in accordance with the figures below. The cost allocator should be mounted on a vertical profile (welding or
gluing), if the profile is not available or the round allocator should be mounted horizontally on the ladders next to the
main collector with the use of grips.