IWM-LR3 - IWM-LR4
10
User Manual v1.0
Payload example
Payload example description
Application code
44
44
Absolute value of the counters (byte 1/4)
XX
74
Absolute value of the counters (byte 2/4)
XX
20
Absolute value of the counters (byte 3/4)
XX
01
Absolute value of the counters (byte 4/4)
XX
00
Reverse flow counter (byte 1/4)
YY
34
Reverse flow counter (byte 2/4)
YY
01
Reverse flow counter (byte 3/4)
YY
00
Reverse flow counter (byte 4/4)
YY
00
Index K
KK
00
Medium
MM
00
VIF
VV
13
Alarms
LL
02
Temperature (byte 1/2)
TT
00
Temperature (byte 2/2)
TT
14
44
74200100
34010000
00
00
13
02
00
14
Application code
44
Absolute value
00012074, formally these are 12074 liter
s
R
everse flow
00000134 so 134 lite
rs
Index
0 (1 liter)
Medium
0 (water)
VIF
13 (liters)
Alarms
(0x02) = Module remove
d
Temperature
00 14 (hex) is 20 (decimal) so +2,0°C