IWM-LR3 - IWM-LR4
User Manual v1.0
3
Correct module startup - Summary
1.
Module provisioning on the network server - Activation on the network
2.
Physical installation of the module on the meter
3.
Joining procedure start-up (+/- 5 rotating index revolutions)
4.
Verification of the module join procedure completion
1. Module provisioning – Activation on the network
Standard devices are configured as OTAA (Over The Air Activation). It is possible to order a batch of devices
configured as ABP (Activation By Personalization).
Standard devices are configured with the AppEUI (a.k.a. JoinEUI) E41E0A90000FFFFF. It is possible to order a
batch of devices configured with a custom unique AppEUI. For this contact B METERS support.
Upon receiving your
IWM-LR3 - IWM-LR4
you can request from B METERS the necessary information to
connect it to your network server. This consists of the following:
-
DevEUI
-
AppKey
These codes are unique for each device. The DevEUI can be seen as a unique identification code, the AppKey is
a securely generated authentication code.
The first step you should take is to simply provision the network server. This can be any LoRa system that you
would like to integrate the sensor with the AppEUI.
The second step is to provision the application server with your unique DevEUI and AppKey.
Digital activation process
-
Provision network server with AppEUI
-
Provision application server with unique DevEUI and AppKey