- 16 -
• Wear protective gloves before
proceeding with the installa-
tion.
• Electric Connection:
Note! Verify the data label placed inside the appliance:
- If the symbol appears on the plate, it means that
no earth connection must be made on the appliance,
therefore follow the instructions concerning insulation
class II.
- If the symbol DOES NOT appear on the plate, follow
the instructions concerning insulation class I.
Insulation class II
- The appliance has been manufactured as a class II,
therefore no earth cable is necessary.
The plug must be easily accessible after the instal-
lation of the appliance. If the appliance is equipped
with power cord without plug, a suitably dimensioned
omnipolar switch with 3 mm minimum opening be-
tween contacts must be fitted between the appliance
and the electricity supply in compliance with the load
and current regulations.
- The connection to the mains is carried out as follows:
BROWN =
L
line
BLUE =
N
neutral.
Insulation class I
This is a class I, appliance and must therefore be con-
nected to an effiecient earthing system.
- The appliance must be connected to the electricity
supply as follows:
BROWN =
L
line
BLUE =
N
neutral
YELLOW/GREEN
= earth.
The neutral wire must be connected to the terminal
with the
N
symbol while the
YELLOW/GREEN
, wire
must be connected to the terminal by the earth
symbol .
When connecting the appliance to the electricity
supply, make sure that the mains socket has an earth
connection. After fitting the ducted cooker hood, make
sure that the electrical plug is in a position where it
can be accessed easily. If the appliance is connected
directly to the electricity supply, an omnipolar switch
with a minimum contact opening of 3 mm must be
placed in between the two; its size must be suitable
for the load required and it must comply with current
legislation.
•
The minimum distance between the support surfaces
of the cooking pots on the cooker top and the lowest
part of the cooker hood must be at least
65 cm
. If a
connection tube composed of two parts is used, the
upper part must be placed outside the lower part. Do
not connect the cooker hood exhaust to the same
conductor used to circulate hot air or for evacuating
fumes from other appliances generated by other
than an electrical source. Before proceeding with the
assembly operations, remove the anti-grease filter(s)
(Fig.9) so that the unit is easier to handle.
- In the case of assembly of the appliance in the suction
version prepare the hole for evacuation of the air.
•
We recommend the use of an air exhaust tube which
has the same diameter as the air exhaust outlet hole.
If a pipe with a smaller diameter is used, the efficiency
of the product may be reduced and its operation may
become noisier.
• Fixing to the wall:
Make hole
A
respecting the shown dimensions (Fig.2).
Fix device to wall and align it horizontally with the
cupboards. When the appliance has been adjusted,
definitely fix the hood using the screws
A
(Fig.6). For
the various installations use screws and screw anchors
suited to the type of wall (e.g. reinforced concrete,
plasterboard, etc.). If the screws and screw anchors are
provided with the product, check that they are suitable
for the type of wall on which the hood is to be fixed.
• Fixing the decorative telescopic flue:
Arrange the electrical power supply within the dimen-
sions of the decorative flue. If your appliance is to be
installed in the ducting version or in the version with
external motor, prepare the air exhaust opening. Install
the upper decorative flue's support bracket and fix it
on the wall using the screws
A
(Fig.3) so it is in axis
with your hood and respecting the distance from the
ceiling shown in Fig.2. Fasten the lower bracket
P
with
the screws
I
(Fig.5). Connect flange
C
to air extraction
hole via an air extraction pipe (Fig.6). Insert upper
decorative flue inside the lower decorative flue and
rest them on top of the frame. Extract the upper flue
up to the bracket and fix it with the screws
B
(Fig.7).
To transform the hood from a ducting version into a
filtering version, ask your dealer for the charcoal filters
and follow the installation instructions.
• Filtering version:
Install the hood and the two flues as described in the
paragraph for installation of the hood in ducting ver-
sion. Connect air diverter
M
(not supplied) to bracket
and fix it with screws
I
as shown in Fig.4. The active
charcoal filters must be applied to the suction unit
inside the hood, centring them in it and turning them
90° until they snap into place (Fig.8).
USE AND MAINTENANCE
•
We recommend that the cooker hood is switched on
before any food is cooked. We also recommend that
the appliance is left running for 15 minutes after the
food is cooked, in order to thoroughly eliminate all
contaminated air. The effective performance of the
cooker hood depends on constant maintenance; the
anti-grease filter and the active carbon filter both
require special attention.
• The anti-grease filter
is responsible retaining the
grease particles suspended in the air, therefore it is
subject to clogging with variable frequency according
to the use of the appliance.
- To prevent the danger of possible fires, at least every 2
months one must wash the anti-grease filters by hand
using non-abrasive neutral liquid detergents or in the
dishwasher at low temperatures and on short cycles.
- After a few washes, colour alterations may occur. This
does not give the right to claim their replacement.
• The active carbon filters
are used to purify the air
that is sent back into the room and its function is to
mitigate the unpleasant odours produced by cooking.
- The non-regenerable active carbon filters must be
replaced at least every 4 months. The saturation of the
active charcoal depends on the more or less prolonged
Summary of Contents for KA7500
Page 2: ......
Page 3: ...3 A B C max 90 cm A I M A 20 mm I P 650 mm Fig 4 Fig 2 Fig 3 Fig 5 Fig 1...
Page 4: ...4 B B C A C A B Fig 6 Fig 8 Fig 12 Fig 7 Fig 9 Fig 11 Fig 10...
Page 23: ......
Page 24: ...3011000109500 00...