Side Burners;

Models with Pilot and/or Flame Failure;

1. 

Ensure the control knob is in the ‘OFF’        position. 

 

2. 

Push knob, and turn knob anti-clockwise to ‘PILOT’        position.

3. 

Whilst keeping the knob pushed in, manually light pilot.

4. 

Continue to hold the knob for 30 seconds after the flame appears on the plot.  Release the knob.  The  

 

pilot should remain lit. If pilot fails to remain lit, push down the control knob and turn clockwise to  

 

the ‘OFF’ position. Wait for five minutes before attempting to re-light (repeat steps 1-4).

5. 

Once pilot flame is established, rotate the knob anti-clockwise to the ‘HIGH’       position.

6. 

Flame size can be reduced by rotating knob anti-clockwise toward ‘LOW’       position.

Models without flame failure;

1. 

Ensure the control knob is in the ‘OFF’ position.  

2. 

Push knob, and turn knob anti-clockwise to ‘LOW’       position.

3. 

Manually light burner.  If burner fails to light, turn knob to ‘OFF’         position and wait for five      

 

minutes before attempting to re-light (repeat steps 1-3).

4. 

Adjust the size of the flame as required by turning knob clockwise towards ‘HIGH’      position.

Shut Down Procedure;

Models with Pilot and/or Flame Failure;

1. 

To turn burner off, turn knob clockwise to the ‘OFF’        position.

2. 

To turn burner off whilst keeping pilot lit, turn knob clockwise to the ‘PILOT’        position.

3. 

To turn pilot off, turn knob clockwise to ‘OFF’        position.

Models without flame failure;

1. 

To turn burner off, turn knob clockwise to ‘OFF’         position.

“OFF” Position

“PILOT” Position (on units fitted with pilot and flame failure)

“HIGH” Position

“LOW” Position

6.  

Once pilot flame is established, turn handle “B” to HIGH.

Shut Down Procedure;

1.  

Turn handle “B” to OFF position.

2.  

Rotate pilot valve knob “A” clockwise to OFF position.

3.  

Observe pilot and main burner flames are extinguished.

Summary of Contents for Verro Series

Page 1: ...mprovements to its products B S Commercial Kitchens Pty Ltd reserves the right to change the product specifications and design without prior notice Manufactured by B S Commercial Kitchens Pty Ltd 57 P...

Page 2: ...eral Information 4 Installation Instuctions 5 Regulations Data Label Ventilation Plinth Mount Gas Connection Pressure Test Point Water Connection 6 Combustible Surfaces 6 Commissioning 7 Gas Component...

Page 3: ...3 A63 D3 D3 Black D Burner 1 2 3 4 Duckbill DB Chimney CB Large Ring 1 2 3 4 Side Burner 1 2 3 4 5 6 Black B Verro E G Donburi D Low LS Plinth P Can lever CL Castor Wheel C Natural Gas NG LPG LPG Eg U...

Page 4: ...THIS APPLIANCE MAY RESULT IN PRODUCT FAILURE WHICH MAY LEAD TO PROPERTY DAMAGE PERSONAL INJURY OR DEATH CAUTION MUST BE TAKEN WHEN OPERATING THIS APPLIANCE TO MINIMISE RISK OF FIRE THE APPLIANCE MUST...

Page 5: ...e it may disrupt airflow to the burner Gas Connection The gas connection is male 3 4 BSP and is situated at the rear of the appliance below the main body frame The number of gas inlets corresponds to...

Page 6: ...ant material may be covered by ceramic tiles or stainless steel to meet appropriate requirements relating to health protection 4 Care should be taken where acombustible surfaceis covered by a non comb...

Page 7: ...a suitably authorised person who a Installed the appliance when gas is available at the time of installation or b makes gas available to the appliance if gas was not available at the time of installat...

Page 8: ...Approved in GMK10348 Round Pilot G0012 SIT Alphabrass Pilot G0186 01 Ensure unit has been leveled prior to finalising commissioning This unit is also available as plinth cantilever and rear locking c...

Page 9: ...lame directly at the pilot housing at a distance no greater than 30mm Push and hold the blue button C 4 Once pilot flame is lit keep the blue button depressed for 15 seconds or until pilot flame stays...

Page 10: ...flame failure 1 Ensure the control knob is in the OFF position 2 Push knob and turn knob anti clockwise to LOW position 3 Manually light burner If burner fails to light turn knob to OFF position and...

Page 11: ...on Inspect burner area and ensure pilots are in position near the burner and that the pilot flame where applicable when ignited is blue in color and approximately 20 40mm in length If fitted with ther...

Page 12: ...s Pty Ltd or their authorised service agent To obtain further service information concerning this appliance pleased contact B S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 P 61 3 94...

Page 13: ...r they shall be at the risk of the purchaser and no liability shall a ach to the company its servants or agents for any damage occasioned to or loan of the goods whatsoever 9 To obtain the benefit of...

Reviews: