10
© B&S Commercial Kitchen Appliances Pty Ltd 2016
Side Burners;
Models with Pilot and/or Flame Failure;
1.
Ensure the control knob is in the ‘OFF’ position.
2.
Push knob, and turn knob anti-clockwise to ‘PILOT’ position.
3.
Whilst keeping the knob pushed in, manually light pilot.
4.
Continue to hold the knob for 30 seconds after the flame appears on the plot. Release the knob. The
pilot should remain lit. If pilot fails to remain lit, push down the control knob and turn clockwise to
the ‘OFF’ position. Wait for five minutes before attempting to re-light (repeat steps 1-4).
5.
Once pilot flame is established, rotate the knob anti-clockwise to the ‘HIGH’ position.
6.
Flame size can be reduced by rotating knob anti-clockwise toward ‘LOW’ position.
Models without flame failure;
1.
Ensure the control knob is in the ‘OFF’ position.
2.
Push knob, and turn knob anti-clockwise to ‘LOW’ position.
3.
Manually light burner. If burner fails to light, turn knob to ‘OFF’ position and wait for five
minutes before attempting to re-light (repeat steps 1-3).
4.
Adjust the size of the flame as required by turning knob clockwise towards ‘HIGH’ position.
Shut Down Procedure;
Models with Pilot and/or Flame Failure;
1.
To turn burner off, turn knob clockwise to the ‘OFF’ position.
2.
To turn burner off whilst keeping pilot lit, turn knob clockwise to the ‘PILOT’ position.
3.
To turn pilot off, turn knob clockwise to ‘OFF’ position.
Models without flame failure;
1.
To turn burner off, turn knob clockwise to ‘OFF’ position.
“OFF” Position
“PILOT” Position (on units fitted with pilot and flame failure)
“HIGH” Position
“LOW” Position
6.
Once pilot flame is established, turn handle “B” to HIGH.
Shut Down Procedure;
1.
Turn handle “B” to OFF position.
2.
Rotate pilot valve knob “A” clockwise to OFF position.
3.
Observe pilot and main burner flames are extinguished.