Gas Components;

Part

Manufacturer

Model No.

Approval Number

Notes

Regulator

Maxitrol

RV48LSM-66/PF10

AGA 3088

Oara

980 (NG)

AGA 5862

986 (LPG)

Ball Valve

Itap SpA

Berlin

AGA 5256

DN 20

London

AGA 6227

DN 20

G.Bee

984 GMK10291

DN 20

Thermcouple

SIT

0200009

Pilot Gas Cock

Keefer Bros

KB628A

AGA 2142

PT

AGA 2144

Alpha Brass

A23-SPT

AGA 7469

Flame Failure Valve (main burner)

SIT

D0440033

AGA 3530

Flame Failure Gas Cock (main burner)

Alpha Brass

A63

AGA 7467

A63, A63V, A63C

Flame Failure Gas Cock (side burner)

PEL Pintossi

21S

AGA 4062

21N

AGA 4062

Alpha Brass

A50

AGA 7467

A60

AGA 7467

Duckbill Burner

DB-18

Chimney Burner

MCB-24

B Side Burner

0096

Approved in GMK10347

E Side Burner

ARC

651 E

Approved in GMK10349

G Side Burner

ARC

651 G

Approved in GMK10349

D Side Burner

GA0090.01

Approved in GMK10348

Round Pilot

G0012

SIT/Alphabrass Pilot

G0186.01

Ensure unit has been leveled prior to finalising commissioning. This unit is also available as plinth, cantilever 

and rear locking castor wheels. When the unit has rear locking castor wheels, front legs must be adjusted to

level the unit.

The commissioning of appliances shall include all of the following, as required by AS5601.1:2010;

(a) - Testing and purging of the appliance and installation as appropriate.

(b) - Checks to ensure the appliance is in safe working order.

(c) - Ignition of each burner of the appliance, and where necessary adjustment in accordane with   

 

        manufacturers instructions.

(d) - Testing of flue performance.

(e) - Testing of all safety devices for correct operation.

(f) - Instruction of the consumer, where available, on the safe and correct operation of the appliance and any        

        auxiliary equipment.

(g) - Handing of the appliance operating instructions to the consumer, or if the consumer is not present,            

         leaving the instructions in a suitable location on the permises.

Summary of Contents for Verro Series

Page 1: ...mprovements to its products B S Commercial Kitchens Pty Ltd reserves the right to change the product specifications and design without prior notice Manufactured by B S Commercial Kitchens Pty Ltd 57 P...

Page 2: ...eral Information 4 Installation Instuctions 5 Regulations Data Label Ventilation Plinth Mount Gas Connection Pressure Test Point Water Connection 6 Combustible Surfaces 6 Commissioning 7 Gas Component...

Page 3: ...3 A63 D3 D3 Black D Burner 1 2 3 4 Duckbill DB Chimney CB Large Ring 1 2 3 4 Side Burner 1 2 3 4 5 6 Black B Verro E G Donburi D Low LS Plinth P Can lever CL Castor Wheel C Natural Gas NG LPG LPG Eg U...

Page 4: ...THIS APPLIANCE MAY RESULT IN PRODUCT FAILURE WHICH MAY LEAD TO PROPERTY DAMAGE PERSONAL INJURY OR DEATH CAUTION MUST BE TAKEN WHEN OPERATING THIS APPLIANCE TO MINIMISE RISK OF FIRE THE APPLIANCE MUST...

Page 5: ...e it may disrupt airflow to the burner Gas Connection The gas connection is male 3 4 BSP and is situated at the rear of the appliance below the main body frame The number of gas inlets corresponds to...

Page 6: ...ant material may be covered by ceramic tiles or stainless steel to meet appropriate requirements relating to health protection 4 Care should be taken where acombustible surfaceis covered by a non comb...

Page 7: ...a suitably authorised person who a Installed the appliance when gas is available at the time of installation or b makes gas available to the appliance if gas was not available at the time of installat...

Page 8: ...Approved in GMK10348 Round Pilot G0012 SIT Alphabrass Pilot G0186 01 Ensure unit has been leveled prior to finalising commissioning This unit is also available as plinth cantilever and rear locking c...

Page 9: ...lame directly at the pilot housing at a distance no greater than 30mm Push and hold the blue button C 4 Once pilot flame is lit keep the blue button depressed for 15 seconds or until pilot flame stays...

Page 10: ...flame failure 1 Ensure the control knob is in the OFF position 2 Push knob and turn knob anti clockwise to LOW position 3 Manually light burner If burner fails to light turn knob to OFF position and...

Page 11: ...on Inspect burner area and ensure pilots are in position near the burner and that the pilot flame where applicable when ignited is blue in color and approximately 20 40mm in length If fitted with ther...

Page 12: ...s Pty Ltd or their authorised service agent To obtain further service information concerning this appliance pleased contact B S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 P 61 3 94...

Page 13: ...r they shall be at the risk of the purchaser and no liability shall a ach to the company its servants or agents for any damage occasioned to or loan of the goods whatsoever 9 To obtain the benefit of...

Reviews: