8
© B&S Commercial Kitchen Appliances Pty Ltd 2016
Gas Components;
Part
Manufacturer
Model No.
Approval Number
Notes
Regulator
Maxitrol
RV48LSM-66/PF10
AGA 3088
Oara
980 (NG)
AGA 5862
986 (LPG)
Ball Valve
Itap SpA
Berlin
AGA 5256
DN 20
London
AGA 6227
DN 20
G.Bee
984 GMK10291
DN 20
Thermcouple
SIT
0200009
Pilot Gas Cock
Keefer Bros
KB628A
AGA 2142
PT
AGA 2144
Alpha Brass
A23-SPT
AGA 7469
Flame Failure Valve (main burner)
SIT
D0440033
AGA 3530
Flame Failure Gas Cock (main burner)
Alpha Brass
A63
AGA 7467
A63, A63V, A63C
Flame Failure Gas Cock (side burner)
PEL Pintossi
21S
AGA 4062
21N
AGA 4062
Alpha Brass
A50
AGA 7467
A60
AGA 7467
Duckbill Burner
DB-18
Chimney Burner
MCB-24
B Side Burner
0096
Approved in GMK10347
E Side Burner
ARC
651 E
Approved in GMK10349
G Side Burner
ARC
651 G
Approved in GMK10349
D Side Burner
GA0090.01
Approved in GMK10348
Round Pilot
G0012
SIT/Alphabrass Pilot
G0186.01
Ensure unit has been leveled prior to finalising commissioning. This unit is also available as plinth, cantilever
and rear locking castor wheels. When the unit has rear locking castor wheels, front legs must be adjusted to
level the unit.
The commissioning of appliances shall include all of the following, as required by AS5601.1:2010;
(a) - Testing and purging of the appliance and installation as appropriate.
(b) - Checks to ensure the appliance is in safe working order.
(c) - Ignition of each burner of the appliance, and where necessary adjustment in accordane with
manufacturers instructions.
(d) - Testing of flue performance.
(e) - Testing of all safety devices for correct operation.
(f) - Instruction of the consumer, where available, on the safe and correct operation of the appliance and any
auxiliary equipment.
(g) - Handing of the appliance operating instructions to the consumer, or if the consumer is not present,
leaving the instructions in a suitable location on the permises.