9
© B&S Commercial Kitchen Appliances Pty Ltd 2016
Lighting Instructions;
OFF POSITION
MIN
MAX
PILOT
30º
90
º
15
0º
OFF
A63 Valve;
1.
Pilot burner is located inside the burner ring. Using a long lighter,
point the lighter flame directly at the pilot housing at a distance no
greater than 30mm.
2.
Turn main gas knob 30º anti-clockwise and push to start pilot gas
flow.
3.
When pilot is alight, hold down main gas knob for approximately 15
seconds, or until thermocouple has warmed sufficiently to maintain
flame.
4.
Once pilot flame is established, rotate main gas knob a further 60º
anti-clockwise to maximum, or a further 120º to minimum.
5.
If pilot flame shuts off prior to establishing, repeat steps 1-4 until
thermocouple has warmed sufficiently to maintain gas flow.
Shut Down Procedure;
1.
Rotate main gas valve knob clockwise to off position.
2.
Observe pilot and main burner flames are extinguished.
D3 Valve;
1.
Turn handle “B” to OFF position mark on sticker.
2.
Turn pilot valve knob “A” anti-clockwise to ON position.
3.
Using a long reach lighter, point the lighter flame directly at the pilot housing at a distance no greater
than 30mm. Push and hold the blue button “C”.
4.
Once pilot flame is lit, keep the blue button depressed for 15 seconds, or until pilot flame stays lit.
5.
If pilot flame shuts off prior to establishing, repeat steps 1-4 until thermocouple has warmed suffi-
ciently to maintain gas flow.
A
B
C
Injector Sizes;
Burner Type
Gas Type
Burner Injector Size
MJ/h per burner
Pilot Injector Size
Test Point Pressure
UFWWSP Injector Sizes
Duckbill (DB)
Natural
1.40mm (x18)
126 MJ/h
1.00mm
1.00 kPa
LPG
0.70mm (x18)
90 MJ/h
0.55mm
2.60 kPa
Chimney (CB)
Natural
1.00mm (x24)
105 MJ/h
1.00mm
1.00 kPa
LPG
0.55mm (x24)
75 MJ/h
0.55mm
2.60 kPa
UFWW Injector Sizes
Duckbill (DB)
Natural
1.25mm (x18)
110 MJ/h
1.00mm
1.00 kPa
LPG
0.70mm (x18)
90 MJ/h
0.55mm
2.60 kPa
Chimney (CB)
Natural
1.00mm (x24)
105 MJ/h
1.00mm
1.00 kPa
LPG
0.55mm (x24)
75 MJ/h
0.55mm
2.60 kPa
Side Burner Injector Sizes
Side Burner B
Natural
2.10mm
20 MJ/h
0.41mm
1.00 kPa
LPG
1.25mm
20 MJ/h
0.25mm
2.60 kPa
Side Burner E
Natural
2.50mm
31 MJ/h
0.45mm
1.00 kPa
LPG
1.45mm
23 MJ/h
0.25mm
2.60 kPa
Side Burner G
Natural
2.70mm
34 MJ/h
0.45mm
1.00 kPa
LPG
1.60mm
30 MJ/h
0.25mm
2.60 kPa
Side Burner D
Natural
1.60mm
12.5 MJ/h
0.41mm
1.00 kPa
LPG
N/A
N/A
N/A
N/A